Quantitative analysis of erythromycylamine in human plasma by liquid chromatography-tandem mass spectrometry and its application in a bioequivalence study of dirithromycin enteric-coated tablets with a special focus on the fragmentation pattern and carryover effect.
J Chromatogr B Analyt Technol Biomed Life Sci
; 947-948: 156-63, 2014 Feb 01.
Article
en En
| MEDLINE
| ID: mdl-24424301
ABSTRACT
A liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of erythromycylamine, which is the predominant active metabolite of dirithromycin in human plasma. After solid-phase extraction, the analyte and internal standard (IS) were separated by using an isocratic mobile phase consisting of 20 mM ammonium acetate (pH 3.9, adjusted with formic acid)-acetonitrile (7525, v/v) on a Phenyl-Hexyl column (150 × 2.1 mm, 3 µm) and then analyzed in positive ion mode under electrospray ionization. Azithromycin was selected as the IS because it has the most similar mass spectrometric and chromatographic behaviors to the analyte. The respective multiple reaction monitoring (MRM) transitions, m/z 368.5>83.2 for erythromycylamine and m/z 375.4>115.2 for IS were chosen to achieve high sensitivity and selectivity in determination. A more acidic mobile phase (pH 3.9) than those of previous reports and a special needle wash (ethylene glycol-acetonitrile-water, 503020, v/v/v, adjusted to pH 3.9 using formic acid) were used to eliminate the carryover effects of the two macrolides. The method exhibited a linear dynamic range of 0.5-440.0 ng/mL for erythromycylamine in human plasma (r=0.9999). The lower limit of quantification (LLOQ) and limit of detection (LOD) were 0.5 and 0.05 ng/mL, respectively. The mean extraction recoveries were higher than 94.0% for the analyte and IS. The intra- and inter-day precisions ranged from 1.4 to 5.4% and from 1.6 to 4.0%, respectively. The accuracy varied between 91.2 and 101.2%. The established method was successfully applied to analyze the human plasma samples from 24 healthy subjects in a bioequivalence study of two dirithromycin enteric-coated formulations.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Contexto en salud:
3_ND
Problema de salud:
3_zoonosis
Asunto principal:
Eritromicina
/
Cromatografía Líquida de Alta Presión
/
Espectrometría de Masas en Tándem
/
Antibacterianos
Tipo de estudio:
Evaluation_studies
Límite:
Adult
/
Animals
/
Female
/
Humans
/
Male
Idioma:
En
Revista:
J Chromatogr B Analyt Technol Biomed Life Sci
Asunto de la revista:
ENGENHARIA BIOMEDICA
Año:
2014
Tipo del documento:
Article