Your browser doesn't support javascript.
loading
Fit for purpose frozen tissue collections by RNA integrity number-based quality control assurance at the Erasmus MC tissue bank.
Kap, Marcel; Oomen, Monique; Arshad, Shazia; de Jong, Bas; Riegman, Peter.
Afiliación
  • Kap M; Department of Pathology, Erasmus Medical Center , Rotterdam, The Netherlands .
Biopreserv Biobank ; 12(2): 81-90, 2014 Apr.
Article en En | MEDLINE | ID: mdl-24749874
About 5000 frozen tissue samples are collected each year by the Erasmus Medical Center tissue bank. Two percent of these samples are randomly selected annually for RNA isolation and RNA Integrity Number (RIN) measurement. A similar quality assessment was conducted during centralization of a 20-year-old tissue collection from the cancer institute, a 15-year-old liver sample archive (-80°C), and a 13-year-old clinical pathology frozen biopsy archive (Liquid Nitrogen). Samples were divided into either high-quality (RIN ≥6.5) or low-quality overall categories, or into four "fit-for-purpose" quality groups: RIN <5: not reliable for demanding downstream analysis; 5 ≤RIN <6: suitable for RT-qPCR; 6 ≤RIN <8: suitable for gene array analysis; and RIN ≥8: suitable for all downstream techniques. In general, low RIN values were correlated with fatty, fibrous, pancreatic, or necrotic tissue. When the percentage of samples with RIN ≥6.5 is higher than 90%, the tissue bank performance is adequate. The annual 2011 quality control assessment showed that 90.3% (n=93) of all samples had acceptable RIN values; 97.4% (n=39) of the cancer institute collection had RIN values above 6.5; and 88.6% (n=123) of samples from the liver sample archive collection had RIN values higher than 6.5. As the clinical pathology biopsy collection contained only 58.8% (n=24) acceptable samples, the procurement protocols used for these samples needed immediate evaluation. When the distribution of RIN values of the different collections were compared, no significant differences were found, despite differences in average storage time and temperature. According to the principle of "fit-for-purpose" distribution, the vast majority of samples are considered good enough for most downstream techniques. In conclusion, an annual tissue bank quality control procedure provides useful information on tissue sample quality and sheds light on where and if improvements need to be made.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 / 2_ODS3 Problema de salud: 1_doencas_nao_transmissiveis / 2_muertes_prematuras_enfermedades_notrasmisibles Asunto principal: Manejo de Especímenes / Bancos de Tejidos Tipo de estudio: Guideline Límite: Humans Idioma: En Revista: Biopreserv Biobank Año: 2014 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 / 2_ODS3 Problema de salud: 1_doencas_nao_transmissiveis / 2_muertes_prematuras_enfermedades_notrasmisibles Asunto principal: Manejo de Especímenes / Bancos de Tejidos Tipo de estudio: Guideline Límite: Humans Idioma: En Revista: Biopreserv Biobank Año: 2014 Tipo del documento: Article País de afiliación: Países Bajos
...