Your browser doesn't support javascript.
loading
Three-dimensional regional strain computation method with displacement encoding with stimulated echoes (DENSE) in non-ischemic, non-valvular dilated cardiomyopathy patients and healthy subjects validated by tagged MRI.
Kar, Julia; Knutsen, Andrew K; Cupps, Brian P; Zhong, Xiaodong; Pasque, Michael K.
Afiliación
  • Kar J; Department of Surgery School of Medicine, Washington University, St Louis, Missouri, USA.
J Magn Reson Imaging ; 41(2): 386-96, 2015 Feb.
Article en En | MEDLINE | ID: mdl-24753028
ABSTRACT

PURPOSE:

Fast cine displacement encoding with stimulated echoes (DENSE) MR has higher spatial resolution and enables rapid postprocessing. Thus we compared the accuracy of regional strains computation by DENSE with tagged MR in healthy and non-ischemic, non-valvular dilated cardiomyopathy (DCM) subjects. MATERIALS AND

METHODS:

Validation of three-dimensional regional strains computed with DENSE was conducted in reference to standard tagged MRI (TMRI) in healthy subjects and patients with DCM. Additional repeatability studies in healthy subjects were conducted to increase confidence in DENSE. A meshfree multiquadrics radial point interpolation method (RPIM) was used for computing Lagrange strains in sixteen left ventricular segments. Bland-Altman analysis and Student's t-tests were conducted to observe similarities in regional strains between sequences and in DENSE repeatability studies.

RESULTS:

Regional circumferential strains ranged from -0.21 ± 0.07 (Lateral-Apex) to -0.11 ± 0.05 (Posterorseptal-Base) in healthy subjects and -0.15 ± 0.04 (Anterior-Apex) to -0.02 ± 0.08 (Posterorseptal-Base) in DCM patients. Computed mean differences in regional circumferential strain from the DENSE-TMRI comparison study was 0.01 ± 0.03 (95% limits of agreement) in normal subjects, -0.01 ± 0.06 in DCM patients and 0.0 ± 0.02 in repeatability studies, with similar agreements in longitudinal and radial strains.

CONCLUSION:

We found agreement between DENSE and tagged MR in patients and volunteers in terms of evaluation of regional strains.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cardiomiopatía Dilatada / Imagen por Resonancia Cinemagnética / Imagenología Tridimensional Límite: Female / Humans / Male / Middle aged Idioma: En Revista: J Magn Reson Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2015 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cardiomiopatía Dilatada / Imagen por Resonancia Cinemagnética / Imagenología Tridimensional Límite: Female / Humans / Male / Middle aged Idioma: En Revista: J Magn Reson Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2015 Tipo del documento: Article País de afiliación: Estados Unidos
...