Your browser doesn't support javascript.
loading
Surgical repair of thoraco-lumbar vertebral fracture-luxations in eight cats using screws and polymethylmethacrylate fixation.
Vallefuoco, R; Manassero, M; Leperlier, D; Scotti, S; Viateau, V; Moissonnier, P.
Afiliación
  • Vallefuoco R; Rosario Vallefuoco Rosario DVM, CHUVA, Ecole Nationale Veterinaire d'Alfort, Department of Small Animal Surgery, 7 Av. du Gen. de Gaulle, Maisons-Alfort, 94700, France, E-mail: rvallefuoco@gmail.com.
Vet Comp Orthop Traumatol ; 27(4): 306-12, 2014.
Article en En | MEDLINE | ID: mdl-24763998
ABSTRACT

OBJECTIVE:

To report our clinical experience in the surgical treatment of feline thoraco-lumbar vertebral fracture-luxations using optimal safe implantation corridors as previously described in vitro. STUDY

DESIGN:

Retrospective clinical study. MATERIALS AND

METHODS:

Medical records and radiographs of cats with vertebral fracture-luxations stabilized by screws and polymethylmethacrylate (PMMA) using optimal safe implantation corridors between 2009 and 2011 were reviewed. For each patient the data included signalment, cause of vertebral fracture-luxations, presence of concurrent injuries, pre- and postoperative neurological grade, surgical treatment, imaging findings, and clinical outcome with short-term (2 weeks) and long-term (12 months) follow-up.

RESULTS:

Eight cats with vertebral fracture-luxations involving the lumbar (L)(n = 5), the thoracic (T) spinal segments (n = 2), or the thoraco-lumbar junction (n = 1) were included in the study. Screws and PMMA were used bilaterally in five cats and unilaterally in three cats. No surgical intra-operative complications using the defined corridors were recorded. Implant failure followed by spontaneous recovery was recorded in one case. Two cats died in the postoperative period (≤ 4 days). The short-term and long-term clinical outcome was excellent in four out of eight cats and satisfactory in two out of eight cats. CONCLUSION AND CLINICAL RELEVANCE This pilot study demonstrates the clinical applicability of optimal safe implantation corridors for stabilization of feline thoraco-lumbar vertebral fracture-luxations with screws and PMMA. This technique can be used with limited risks of iatrogenic injuries for stabilization of vertebral fracture-luxation localized between T11-L4.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vértebras Torácicas / Tornillos Óseos / Enfermedades de los Gatos / Luxaciones Articulares / Fracturas Óseas / Vértebras Lumbares Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Animals Idioma: En Revista: Vet Comp Orthop Traumatol Asunto de la revista: MEDICINA VETERINARIA / ORTOPEDIA / TRAUMATOLOGIA Año: 2014 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vértebras Torácicas / Tornillos Óseos / Enfermedades de los Gatos / Luxaciones Articulares / Fracturas Óseas / Vértebras Lumbares Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Animals Idioma: En Revista: Vet Comp Orthop Traumatol Asunto de la revista: MEDICINA VETERINARIA / ORTOPEDIA / TRAUMATOLOGIA Año: 2014 Tipo del documento: Article
...