Acoustic output measured by thermal and mechanical indices during fetal echocardiography at the time of the first trimester scan.
Nemescu, Dragos; Berescu, Anca.
Afiliación
  • Nemescu D; Department of Obstetrics and Gynecology, University of Medicine and Pharmacy "Gr. T. Popa", Iasi, Romania; "Cuza Voda" Obstetrics & Gynecology Hospital, Iasi, Romania. Electronic address: dragos.nemescu@umfiasi.ro.
  • Berescu A; "Cuza Voda" Obstetrics & Gynecology Hospital, Iasi, Romania.
Ultrasound Med Biol ; 41(1): 35-9, 2015 Jan.
Article en En | MEDLINE | ID: mdl-25438839
We measured acoustic output, expressed as the thermal index (TI) and mechanical index (MI), during fetal echocardiography at the time of the first trimester scan. TI and MI were retrieved from the saved displays during gray-mode, high-definition color flow Doppler and pulsed-wave Doppler (tricuspid flow) ultrasound examinations of the fetal heart and from the ductus venosus assessment. A total of 399 fetal cardiac examinations were evaluated. There was a significant increase in TI values from B-mode studies (0.07 ± 0.04 [mean ± SD]) to color flow mapping (0.2 ± 0.0) and pulsed-wave Doppler studies (0.36 ± 0.05). The TI from ductus venosus assessment (0.1 ± 0.01) was significantly lower than those from Doppler examinations of the heart. MI values from B-mode scans (0.65 ± 0.12) and color flow mapping (0.71 ± 0.11) were comparable, although different, and both values were higher than those from pulsed-wave Doppler tricuspid evaluation (0.39 ± 0.03). There were no differences in MI values from power Doppler assessment between the tricuspid flow and ductus venosus. Safety indices were remarkably stable and were largely constant, especially for color Doppler (TI), tricuspid flow (MI) and ductus venosus assessment (TI, MI). We acquired satisfactory Doppler images and/or signals at acoustic levels that were lower than the actual recommendations and never reached a TI of 0.5.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Primer Trimestre del Embarazo / Temperatura Corporal / Ecocardiografía / Ultrasonografía Prenatal / Corazón Fetal Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adolescent / Adult / Female / Humans / Pregnancy Idioma: En Revista: Ultrasound Med Biol Año: 2015 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Primer Trimestre del Embarazo / Temperatura Corporal / Ecocardiografía / Ultrasonografía Prenatal / Corazón Fetal Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adolescent / Adult / Female / Humans / Pregnancy Idioma: En Revista: Ultrasound Med Biol Año: 2015 Tipo del documento: Article
...