Your browser doesn't support javascript.
loading
Optimized precursor ion selection for labile ions in a linear ion trap mass spectrometer and its impact on quantification using selected reaction monitoring.
Lee, Hyun-Seok; Shin, Kyong-Oh; Jo, Sung-Chan; Lee, Yong-Moon; Yim, Yong-Hyeon.
Afiliación
  • Lee HS; College of Pharmacy, Chungbuk National University, 52 Naesudong-ro, Heungdeok-gu, Cheongju, Chungbuk, 361-763, Korea; Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejeon, 305-340, Korea.
J Mass Spectrom ; 49(12): 1234-8, 2014 Dec.
Article en En | MEDLINE | ID: mdl-25476940
ABSTRACT
The fragmentation of fragile ions during the application of an isolation waveform for precursor ion selection and the resulting loss of isolated ion intensity is well-known in ion trap mass spectrometry (ITMS). To obtain adequate ion intensity in the selected reaction monitoring (SRM) of fragile precursor ions, a wider ion isolation width is required. However, the increased isolation width significantly diminishes the selectivity of the channels chosen for SRM, which is a serious problem for samples with complex matrices. The sensitive and selective quantification of many lipid molecules, including ceramides from real biological samples, using a linear ion trap mass spectrometer is also hindered by the same problem because of the ease of water loss from protonated ceramide ions. In this study, a method for the reliable quantification of ceramides using SRM with near unity precursor ion isolation has been developed for ITMS by utilizing alternative precursor ions generated by in-source dissociation. The selected precursor ions allow the isolation of ions with unit mass width and the selective analysis of ceramides using SRM with negligible loss of sensitivity. The quantification of C180-, C240- and C241-ceramides using the present method shows excellent linearity over the concentration ranges from 6 to 100, 25 to 1000 and 25 to 1000 nM, respectively. The limits of detection of C180-, C240- and C241-ceramides were 0.25, 0.25 and 5 fmol, respectively. The developed method was successfully applied to quantify ceramides in fetal bovine serum.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ceramidas / Espectrometría de Masas en Tándem Límite: Animals Idioma: En Revista: J Mass Spectrom Asunto de la revista: BIOQUIMICA Año: 2014 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ceramidas / Espectrometría de Masas en Tándem Límite: Animals Idioma: En Revista: J Mass Spectrom Asunto de la revista: BIOQUIMICA Año: 2014 Tipo del documento: Article
...