Your browser doesn't support javascript.
loading
Fluorescence sensing of chromium (VI) and ascorbic acid using graphitic carbon nitride nanosheets as a fluorescent "switch".
Rong, Mingcong; Lin, Liping; Song, Xinhong; Wang, Yiru; Zhong, Yunxin; Yan, Jiawei; Feng, Yufeng; Zeng, Xiuya; Chen, Xi.
Afiliación
  • Rong M; Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
  • Lin L; Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
  • Song X; Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
  • Wang Y; Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
  • Zhong Y; Department of Chemistry, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
  • Yan J; Department of Chemistry, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
  • Feng Y; the First Affiliated Hospital of Xiamen University, Xiamen University, Xiamen 361005, China.
  • Zeng X; the First Affiliated Hospital of Xiamen University, Xiamen University, Xiamen 361005, China.
  • Chen X; Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China; State Key Laboratory of Marine Environmental Science, Xiamen University, Xiamen 361005, China. Electronic addr
Biosens Bioelectron ; 68: 210-217, 2015 Jun 15.
Article en En | MEDLINE | ID: mdl-25574860
Using graphitic carbon nitride (g-C3N4) nanosheets, an effective and facile fluorescence sensing approach for the label-free and selective determination of chromium (VI) (Cr(VI)) was developed. The fluorescence of the solution of g-C3N4 nanosheets was quenched effectively by Cr(VI) via the inner filter effect. Under optimal conditions, a wide detection linear range for Cr(VI) was found to be from 0.6 µM to 300 µM with a limit of detection (LOD) of 0.15 µM. In addition, the fluorescence of the solution of g-C3N4 nanosheets-Cr(VI) could be sensitively turned on in the presence of a reductant such as ascorbic acid (AA) via an "on-off-on" fluorescence response through the oxidation-reduction between Cr(VI) and AA. And a wide detection linear range for AA was found to be from 0.5 µM to 200 µM with an LOD of 0.13 µM. Furthermore, the proposed method has the potential application for detection of Cr(VI) in lake waters and AA in biological fluids.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ácido Ascórbico / Contaminantes Químicos del Agua / Técnicas Biosensibles / Cromo Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2015 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ácido Ascórbico / Contaminantes Químicos del Agua / Técnicas Biosensibles / Cromo Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2015 Tipo del documento: Article País de afiliación: China
...