Your browser doesn't support javascript.
loading
Multicentre comparison Of shock efficacy using single-vs. Dual-coil lead systems and Anodal vs. cathodaL polarITY defibrillation in patients undergoing transvenous cardioverter-defibrillator implantation. The MODALITY study.
J Interv Card Electrophysiol ; 43(1): 45-54, 2015 Jun.
Article en En | MEDLINE | ID: mdl-25690336
ABSTRACT

PURPOSE:

An optimal active-can lead configuration during implantable cardioverter defibrillator (ICD) placement is important to obtain an adequate defibrillation safety margin. The purpose of this multicenter study was to evaluate the rate of the first shock success at defibrillation testing according to the type of lead implant (single vs. dual coil) and shock polarity (cathodal and anodal) in a large series of consecutive patients who received transvenous ICDs.

METHODS:

This was a multicenter study enrolling 469 consecutive patients. Single- versus dual-coil leads and cathodal versus anodal polarity were evaluated at defibrillation testing. In all cases, the value of the energy for the first shock was set to 20 J less than the maximum energy deliverable from the device.

RESULTS:

A total of 469 patients underwent defibrillation testing 158 (34 %) had dual-coil and 311 (66 %) had single-coil lead systems configuration, 254 (54 %) received anodal shock and 215 (46 %) received cathodal shock. In 35 (7.4 %) patients, the shock was unsuccessful. No significant differences in the outcome of defibrillation testing using single- versus dual-coil lead were observed but the multivariate analysis showed an increased risk of shock failure using cathodal shock polarity (OR 2.37, 95 % CI 1.12-5.03).

CONCLUSIONS:

Both single- and dual-coil transvenous ICD lead systems were associated with high rates of successful ICD implantation, and we found no significant differences in ventricular arrhythmias interruption between the two ICD lead systems configuration. Instead, anodal defibrillation was more likely to be successful than cathodal defibrillation.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fibrilación Ventricular / Cardioversión Eléctrica / Desfibriladores Implantables / Implantación de Prótesis / Técnicas Electrofisiológicas Cardíacas Tipo de estudio: Clinical_trials / Diagnostic_studies Límite: Aged / Female / Humans / Male País/Región como asunto: Europa Idioma: En Revista: J Interv Card Electrophysiol Asunto de la revista: CARDIOLOGIA Año: 2015 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fibrilación Ventricular / Cardioversión Eléctrica / Desfibriladores Implantables / Implantación de Prótesis / Técnicas Electrofisiológicas Cardíacas Tipo de estudio: Clinical_trials / Diagnostic_studies Límite: Aged / Female / Humans / Male País/Región como asunto: Europa Idioma: En Revista: J Interv Card Electrophysiol Asunto de la revista: CARDIOLOGIA Año: 2015 Tipo del documento: Article
...