Your browser doesn't support javascript.
loading
Determination of geniposide in adjuvant arthritis rat plasma by ultra-high performance liquid chromatography tandem mass spectrometry method and its application to oral bioavailability and plasma protein binding ability studies.
Chen, Jian; Wu, Hong; Xu, Guo-Bing; Dai, Miao-Miao; Hu, Shun-Li; Sun, Liang-Liang; Wang, Wei; Wang, Rong; Li, Shu-Pin; Li, Guo-Qiang.
Afiliación
  • Chen J; College of Pharmacy, Anhui University of Chinese Medicine, Key Laboratory of Modernized Chinese Medicine in Anhui Province, Hefei, Anhui, China.
  • Wu H; College of Pharmacy, Anhui University of Chinese Medicine, Key Laboratory of Modernized Chinese Medicine in Anhui Province, Hefei, Anhui, China. Electronic address: hongw@aliyun.com.
  • Xu GB; Anhui Institute for Drug Control, Hefei, Anhui, China.
  • Dai MM; College of Pharmacy, Anhui University of Chinese Medicine, Key Laboratory of Modernized Chinese Medicine in Anhui Province, Hefei, Anhui, China.
  • Hu SL; College of Pharmacy, Anhui University of Chinese Medicine, Key Laboratory of Modernized Chinese Medicine in Anhui Province, Hefei, Anhui, China.
  • Sun LL; College of Pharmacy, Anhui University of Chinese Medicine, Key Laboratory of Modernized Chinese Medicine in Anhui Province, Hefei, Anhui, China.
  • Wang W; College of Pharmacy, Anhui University of Chinese Medicine, Key Laboratory of Modernized Chinese Medicine in Anhui Province, Hefei, Anhui, China.
  • Wang R; College of Pharmacy, Anhui University of Chinese Medicine, Key Laboratory of Modernized Chinese Medicine in Anhui Province, Hefei, Anhui, China.
  • Li SP; College of Pharmacy, Anhui University of Chinese Medicine, Key Laboratory of Modernized Chinese Medicine in Anhui Province, Hefei, Anhui, China.
  • Li GQ; College of Pharmacy, Anhui University of Chinese Medicine, Key Laboratory of Modernized Chinese Medicine in Anhui Province, Hefei, Anhui, China.
J Pharm Biomed Anal ; 108: 122-8, 2015 Apr 10.
Article en En | MEDLINE | ID: mdl-25771205
ABSTRACT
A specific, sensitive and high throughput ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometric method (UHPLC-ESI-MS/MS) was established and validated to assay geniposide (GE), a promising anti-inflammatory drug, in adjuvant arthritis rat plasma application to pharmacokinetic and oral bioavailability studies and plasma protein binding ability. Plasma samples were processed by de-proteinised with ice-cold methanol and separated on an ACQUITY UPLC™ HSS C18 column (100 mm × 2.1mm i.d., 1.8 µm particle size) at a gradient flow rate of 0.2 mL/min using acetonitrile-0.1% formic acid in water as mobile phase, and the total run time was 9 min. Mass detection was performed in selected reaction monitoring (SRM) mode with negative electro-spray ionization includes the addition of paeoniflorin (Pae) as an internal standard (IS). The mass transition ion-pair was followed as m/z 387.4 → 122.4 for GE and m/z 479.4 → 449.0 for IS. The calibration curves were linear over the concentration range of 2-50,000 ng/mL with lower limit of quantification of 2 ng/mL. The intra-day and inter-day precisions (RSD, %) of the assay were less than 8.4%, and the accuracy was within ± 6.4% in terms of relative error (RE). Extraction recovery, matrix effect and stability were satisfactory in adjuvant arthritis rat plasma. The UHPLC-ESI-MS/MS method was successfully applied to a pharmacokinetic study of GE after oral administration of depurated GE at 33, 66, 132 mg/kg and intravenous injection at 33, 66, 132 mg/kg in adjuvant arthritis (AA) rats. In addition, it was found that GE has rapid absorption and elimination, low absolute bioavailability, high plasma protein binding ability in AA rats after oral administration within the tested dosage range. It suggested that GE showed slow distribution into the intra- and extracellular space, and the binding rate was not proportionally dependent on plasma concentration of GE when the concentration of GE was below 5.0 µg/mL.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cromatografía Líquida de Alta Presión / Espectrometría de Masa por Ionización de Electrospray / Iridoides / Espectrometría de Masas en Tándem Tipo de estudio: Diagnostic_studies Límite: Animals Idioma: En Revista: J Pharm Biomed Anal Año: 2015 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cromatografía Líquida de Alta Presión / Espectrometría de Masa por Ionización de Electrospray / Iridoides / Espectrometría de Masas en Tándem Tipo de estudio: Diagnostic_studies Límite: Animals Idioma: En Revista: J Pharm Biomed Anal Año: 2015 Tipo del documento: Article País de afiliación: China
...