Your browser doesn't support javascript.
loading
Marginal bone-level alterations of loaded zirconia and titanium dental implants: an experimental study in the dog mandible.
Thoma, Daniel S; Benic, Goran I; Muñoz, Fernando; Kohal, Ralf; Sanz Martin, Ignacio; Cantalapiedra, Antonio G; Hämmerle, Christoph H F; Jung, Ronald E.
Afiliación
  • Thoma DS; Clinic for Fixed and Removable Prosthodontics and Dental Material Science, University of Zurich, Zurich, Switzerland.
  • Benic GI; Clinic for Fixed and Removable Prosthodontics and Dental Material Science, University of Zurich, Zurich, Switzerland.
  • Muñoz F; Department of Veterinary Clinical Sciences, University of Santiago de Compostela, Lugo, Spain.
  • Kohal R; Department of Prosthodontics, Albert-Ludwigs-University, Freiburg, Germany.
  • Sanz Martin I; Universidad Complutense, Madrid, Spain.
  • Cantalapiedra AG; Department of Veterinary Clinical Sciences, University of Santiago de Compostela, Lugo, Spain.
  • Hämmerle CH; Clinic for Fixed and Removable Prosthodontics and Dental Material Science, University of Zurich, Zurich, Switzerland.
  • Jung RE; Clinic for Fixed and Removable Prosthodontics and Dental Material Science, University of Zurich, Zurich, Switzerland.
Clin Oral Implants Res ; 27(4): 412-20, 2016 Apr.
Article en En | MEDLINE | ID: mdl-25864523
ABSTRACT

OBJECTIVES:

The aim was to test whether or not the marginal bone-level alterations of loaded zirconia implants are similar to the bone-level alterations of a grade 4 titanium one-piece dental implant. MATERIALS AND

METHODS:

In six dogs, all premolars and the first molars were extracted in the mandible. Four months later, three zirconia implants (BPI, VC, ZD) and a control titanium one-piece (STM) implant were randomly placed in each hemimandible and left for transmucosal healing (baseline). Six months later, CAD/CAM crowns were cemented. Sacrifice was scheduled at 6-month postloading. Digital X-rays were taken at implant placement, crowns insertion, and sacrifice. Marginal bone-level alterations were calculated, and intra- and intergroup comparisons performed adjusted by confounding factors.

RESULTS:

Implants were successfully placed. Until crown insertion, two implants were fractured (one VC, one ZD). At sacrifice, 5 more implants were (partly) fractured (one BPI, four ZD), and one lost osseointegration (VC). No decementation of crowns occurred. All implant systems demonstrated a statistically significant (except VC) loss of marginal bone between baseline and crown insertion ranging from 0.29 mm (VC; P = 0.116) to 0.80 mm (ZD; P = 0.013). The estimated marginal bone loss between baseline and 6 months of loading ranged between 0.19 mm (BPI) and 1.11 mm (VC), being statistically significant for STM and VC only (P < 0.05). The changes in marginal bone levels were statistically significantly different between zirconia implants and control implants (STM vs. BPI P = 0.007; vs. VC P = 0.001; vs. ZD P = 0.011).

CONCLUSIONS:

Zirconia implants were more prone to fracture prior to and after loading with implant-supported crowns compared to titanium implants. Individual differences and variability in the extent of the bone-level changes during the 12-month study period were found between the different implant types and materials.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Titanio / Circonio / Implantes Dentales / Pérdida de Hueso Alveolar / Implantación Dental Endoósea Límite: Animals Idioma: En Revista: Clin Oral Implants Res Asunto de la revista: ODONTOLOGIA Año: 2016 Tipo del documento: Article País de afiliación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Titanio / Circonio / Implantes Dentales / Pérdida de Hueso Alveolar / Implantación Dental Endoósea Límite: Animals Idioma: En Revista: Clin Oral Implants Res Asunto de la revista: ODONTOLOGIA Año: 2016 Tipo del documento: Article País de afiliación: Suiza
...