Your browser doesn't support javascript.
loading
Comparison of the provocative concentration of methacholine causing a 20% fall in FEV1 between the AeroEclipse II breath-actuated nebulizer and the wright nebulizer in adult subjects with asthma.
El-Gammal, Amani I; Killian, Kieran J; Scime, Tara X; Beaudin, Suzanne; Schlatman, Abbey; Cockcroft, Donald W; Gauvreau, Gail M.
Afiliación
  • El-Gammal AI; 1 Department of Medicine, McMaster University, Hamilton, Ontario, Canada; and.
  • Killian KJ; 1 Department of Medicine, McMaster University, Hamilton, Ontario, Canada; and.
  • Scime TX; 1 Department of Medicine, McMaster University, Hamilton, Ontario, Canada; and.
  • Beaudin S; 1 Department of Medicine, McMaster University, Hamilton, Ontario, Canada; and.
  • Schlatman A; 1 Department of Medicine, McMaster University, Hamilton, Ontario, Canada; and.
  • Cockcroft DW; 2 Department of Medicine, University of Saskatchewan, Saskatoon, Saskatchewan, Canada.
  • Gauvreau GM; 1 Department of Medicine, McMaster University, Hamilton, Ontario, Canada; and.
Ann Am Thorac Soc ; 12(7): 1039-43, 2015 Jul.
Article en En | MEDLINE | ID: mdl-25871542
RATIONALE: The American Thoracic Society guidelines for methacholine testing for the diagnosis of asthma recommends the 2-minute tidal breathing protocol with the Wright nebulizer, which produces more aerosol than required, generates a small particle size, and requires cleaning between tests. OBJECTIVES: To evaluate methacholine testing using a disposable, breath-actuated AeroEclipse II, which produces aerosol during inspiration and was developed for single-patient use. METHODS: Forty-six adult subjects with asthma (19 men), aged 27.3 (SD, 9.5) years, with FEV1 98.5 (SD, 18.1) % predicted participated in a randomized, crossover, observational study. Subjects were first screened using the Wright nebulizer, then assigned to 2 minutes of tidal breathing from the Wright or 20 seconds of tidal breathing from the AeroEclipse nebulizer on 2 separate days, in random order. Provocative concentration of methacholine causing a 20% fall in FEV1 (PC20) values were calculated by linear interpolation of log dose-versus-response curves, log-transformed, and compared using paired Student t test and Pearson correlation. MEASUREMENTS AND MAIN RESULTS: The 38 subjects demonstrating reproducible PC20 measurements of within 1.5 doubling concentrations were included in the comparison. The geometric mean methacholine PC20 measured with the AeroEclipse nebulizer was approximately 1 doubling concentration lower than the geometric mean methacholine PC20 of the Wright nebulizer (P < 0.05). The Pearson correlation coefficient between the two nebulizers was 0.86 (P < 0.05). CONCLUSIONS: The PC20 measurements using the two nebulizers were highly correlated; however, the PC20 determined with the AeroEclipse nebulizer was significantly lower than those determined using the Wright nebulizer. Clinical trial registered with www.clinicaltrials.gov (NCT 01919424).
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Asma / Nebulizadores y Vaporizadores / Pruebas de Provocación Bronquial / Cloruro de Metacolina / Hiperreactividad Bronquial Tipo de estudio: Clinical_trials / Guideline / Observational_studies / Prognostic_studies Límite: Adolescent / Adult / Female / Humans / Male Idioma: En Revista: Ann Am Thorac Soc Año: 2015 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Asma / Nebulizadores y Vaporizadores / Pruebas de Provocación Bronquial / Cloruro de Metacolina / Hiperreactividad Bronquial Tipo de estudio: Clinical_trials / Guideline / Observational_studies / Prognostic_studies Límite: Adolescent / Adult / Female / Humans / Male Idioma: En Revista: Ann Am Thorac Soc Año: 2015 Tipo del documento: Article
...