Your browser doesn't support javascript.
loading
New beam monitoring tool for radiobiology experiments at the cyclotron ARRONAX.
Schwob, L; Koumeir, C; Servagent, N; Cherel, M; Guertin, A; Haddad, F; Métivier, V; Michel, N; Poirier, F; Rahmani, A; Varmenot, N.
Afiliación
  • Schwob L; GIP ARRONAX, Saint Herblain, France.
  • Koumeir C; GIP ARRONAX, Saint Herblain, France SUBATECH, Ecole des Mines de Nantes, CNRS/IN2P3, Université de Nantes, Nantes charbel.koumeir@subatech.in2p3.fr.
  • Servagent N; SUBATECH, Ecole des Mines de Nantes, CNRS/IN2P3, Université de Nantes, Nantes.
  • Cherel M; INSERM, CRCNA, Nantes, France.
  • Guertin A; SUBATECH, Ecole des Mines de Nantes, CNRS/IN2P3, Université de Nantes, Nantes.
  • Haddad F; GIP ARRONAX, Saint Herblain, France SUBATECH, Ecole des Mines de Nantes, CNRS/IN2P3, Université de Nantes, Nantes.
  • Métivier V; SUBATECH, Ecole des Mines de Nantes, CNRS/IN2P3, Université de Nantes, Nantes.
  • Michel N; GIP ARRONAX, Saint Herblain, France SUBATECH, Ecole des Mines de Nantes, CNRS/IN2P3, Université de Nantes, Nantes.
  • Poirier F; GIP ARRONAX, Saint Herblain, France SUBATECH, Ecole des Mines de Nantes, CNRS/IN2P3, Université de Nantes, Nantes.
  • Rahmani A; SUBATECH, Ecole des Mines de Nantes, CNRS/IN2P3, Université de Nantes, Nantes.
  • Varmenot N; GIP ARRONAX, Saint Herblain, France Institut de Cancérologie de L'Ouest (ICO-R. Gauducheau), Saint Herblain, France.
Radiat Prot Dosimetry ; 166(1-4): 257-60, 2015 Sep.
Article en En | MEDLINE | ID: mdl-25897142
ABSTRACT
The ARRONAX cyclotron is able to deliver alpha particles at 68 MeV. In the frame of radiological research, a new method is studied to infer in situ the deposited dose it is based on the online measurement of the bremsstrahlung (>1 keV) produced by the interaction of the incident particle with the medium. Experiments are made using bombarded poly(methyl methacrylate) (PMMA)-equivalent water targets in order to characterise this continuous X-ray spectrum. The intensity of the bremsstrahlung spectrum allows for the beam monitoring. A simulation code of the bremsstrahlung has been built, and a good agreement is found with the experimental spectra. With this simulation, it is possible to predict the sensibility of this

method:

it varies with the target thickness, showing a good sensibility for thin target (<1000 µm) and saturation for thicker ones. Bremsstrahlung spectrum also shows a sensibility on the target's chemical composition.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 Problema de salud: 1_financiamento_saude Asunto principal: Radiobiología / Planificación de la Radioterapia Asistida por Computador / Ciclotrones / Polimetil Metacrilato / Modelos Teóricos Tipo de estudio: Health_economic_evaluation / Prognostic_studies Idioma: En Revista: Radiat Prot Dosimetry Año: 2015 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 Problema de salud: 1_financiamento_saude Asunto principal: Radiobiología / Planificación de la Radioterapia Asistida por Computador / Ciclotrones / Polimetil Metacrilato / Modelos Teóricos Tipo de estudio: Health_economic_evaluation / Prognostic_studies Idioma: En Revista: Radiat Prot Dosimetry Año: 2015 Tipo del documento: Article País de afiliación: Francia
...