Accelerating T1ρ cartilage imaging using compressed sensing with iterative locally adapted support detection and JSENSE.
Zhou, Yihang; Pandit, Prachi; Pedoia, Valentina; Rivoire, Julien; Wang, Yanhua; Liang, Dong; Li, Xiaojuan; Ying, Leslie.
Afiliación
  • Zhou Y; Department of Biomedical Engineering, Department of Electrical Engineering, State University of New York at Buffalo, Buffalo, USA.
  • Pandit P; Department of Radiology and Biomedical Imaging, University of California, San Francisco, USA.
  • Pedoia V; Department of Radiology and Biomedical Imaging, University of California, San Francisco, USA.
  • Rivoire J; Department of Radiology and Biomedical Imaging, University of California, San Francisco, USA.
  • Wang Y; Department of Biomedical Engineering, Department of Electrical Engineering, State University of New York at Buffalo, Buffalo, USA.
  • Liang D; School of Information and Electronics, Beijing Institute of Technology, Beijing, China.
  • Li X; Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Key Laboratory for MRI, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China.
  • Ying L; Department of Radiology and Biomedical Imaging, University of California, San Francisco, USA.
Magn Reson Med ; 75(4): 1617-29, 2016 Apr.
Article en En | MEDLINE | ID: mdl-26010735
ABSTRACT

PURPOSE:

To accelerate T1ρ quantification in cartilage imaging using combined compressed sensing with iterative locally adaptive support detection and JSENSE.

METHODS:

To reconstruct T1ρ images from accelerated acquisition at different time of spin-lock (TSLs), we propose an approach to combine an advanced compressed sensing (CS) based reconstruction technique, LAISD (locally adaptive iterative support detection), and an advanced parallel imaging technique, JSENSE. Specifically, the reconstruction process alternates iteratively among local support detection in the domain of principal component analysis, compressed sensing reconstruction of the image sequence, and sensitivity estimation with JSENSE. T1ρ quantification results from accelerated scans using the proposed method are evaluated using in vivo knee cartilage data from bilateral scans of three healthy volunteers.

RESULTS:

T1ρ maps obtained from accelerated scans (acceleration factors of 3 and 3.5) using the proposed method showed results comparable to conventional full scans. The T1ρ errors in all compartments are below 1%, which is well below the in vivo reproducibility of cartilage T1ρ reported from previous studies.

CONCLUSION:

The proposed method can significantly accelerate the acquisition process of T1ρ quantification on human cartilage imaging without sacrificing accuracy, which will greatly facilitate the clinical translation of quantitative cartilage MRI.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Imagen por Resonancia Magnética / Cartílago Articular / Articulación de la Rodilla Tipo de estudio: Diagnostic_studies Límite: Adult / Humans Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2016 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Imagen por Resonancia Magnética / Cartílago Articular / Articulación de la Rodilla Tipo de estudio: Diagnostic_studies Límite: Adult / Humans Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2016 Tipo del documento: Article País de afiliación: Estados Unidos
...