Your browser doesn't support javascript.
loading
A wearable wound moisture sensor as an indicator for wound dressing change: an observational study of wound moisture and status.
Milne, Stephen D; Seoudi, Ihab; Al Hamad, Hanadi; Talal, Talal K; Anoop, Anzila A; Allahverdi, Niloofar; Zakaria, Zain; Menzies, Robert; Connolly, Patricia.
Afiliación
  • Milne SD; Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK.
  • Seoudi I; Continuing Care Group, Hamad Medical Corporation, Doha, Qatar.
  • Al Hamad H; Continuing Care Group, Hamad Medical Corporation, Doha, Qatar.
  • Talal TK; Hamad General Hospital, Hamad Medical Corporation, Doha, Qatar.
  • Anoop AA; Continuing Care Group, Hamad Medical Corporation, Doha, Qatar.
  • Allahverdi N; Continuing Care Group, Hamad Medical Corporation, Doha, Qatar.
  • Zakaria Z; Continuing Care Group, Hamad Medical Corporation, Doha, Qatar.
  • Menzies R; Hamad General Hospital, Hamad Medical Corporation, Doha, Qatar.
  • Connolly P; Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK.
Int Wound J ; 13(6): 1309-1314, 2016 Dec.
Article en En | MEDLINE | ID: mdl-26561281
ABSTRACT
Wound moisture is known to be a key parameter to ensure optimum healing conditions in wound care. This study tests the moisture content of wounds in normal practice in order to observe the moisture condition of the wound at the point of dressing change. This study is also the first large-scale observational study that investigates wound moisture status at dressing change. The WoundSense sensor is a commercially available moisture sensor which sits directly on the wound in order to find the moisture status of the wound without disturbing or removing the dressing. The results show that of the 588 dressing changes recorded, 44·9% were made when the moisture reading was in the optimum moisture zone. Of the 30 patients recruited for this study, 11 patients had an optimum moisture reading for at least 50% of the measurements before dressing change. These results suggest that a large number of unnecessary dressing changes are being made. This is a significant finding of the study as it suggests that the protocols currently followed can be modified to allow fewer dressing changes and less disturbance of the healing wound bed.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vendajes / Cicatrización de Heridas / Heridas y Lesiones / Exudados y Transudados / Monitoreo Fisiológico Tipo de estudio: Etiology_studies / Guideline / Incidence_studies / Observational_studies / Risk_factors_studies Límite: Female / Humans / Male Idioma: En Revista: Int Wound J Año: 2016 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vendajes / Cicatrización de Heridas / Heridas y Lesiones / Exudados y Transudados / Monitoreo Fisiológico Tipo de estudio: Etiology_studies / Guideline / Incidence_studies / Observational_studies / Risk_factors_studies Límite: Female / Humans / Male Idioma: En Revista: Int Wound J Año: 2016 Tipo del documento: Article País de afiliación: Reino Unido
...