Your browser doesn't support javascript.
loading
Neck motion kinematics: an inter-tester reliability study using an interactive neck VR assessment in asymptomatic individuals.
Sarig Bahat, Hilla; Sprecher, Elliot; Sela, Itamar; Treleaven, Julia.
Afiliación
  • Sarig Bahat H; Department of Physical Therapy, Faculty of Social Welfare and Health Sciences, University of Haifa, Mount Carmel, 31905, Haifa, Israel. hbahat@physicalvirtue.co.il.
  • Sprecher E; Department of Physical Therapy, Faculty of Social Welfare and Health Sciences, University of Haifa, Mount Carmel, 31905, Haifa, Israel.
  • Sela I; The Edmond J. Safra Brain Research Center for the Study of Learning Disabilities, University of Haifa, 31905, Haifa, Israel.
  • Treleaven J; CCRE Spine, Division of Physiotherapy, School of Health and Rehabilitation Science, The University of Queensland, Brisbane, QLD, 4072, Australia.
Eur Spine J ; 25(7): 2139-48, 2016 07.
Article en En | MEDLINE | ID: mdl-26831536
ABSTRACT
BACKGROUND AND

PURPOSE:

The use of virtual reality (VR) for assessment and intervention of neck pain has previously been used and shown reliable for cervical range of motion measures. Neck VR enables analysis of task-oriented neck movement by stimulating responsive movements to external stimuli. Therefore, the purpose of this study was to establish inter-tester reliability of neck kinematic measures so that it can be used as a reliable assessment and treatment tool between clinicians.

METHODS:

This reliability study included 46 asymptomatic participants, who were assessed using the neck VR system which displayed an interactive VR scenario via a head-mounted device, controlled by neck movements. The objective of the interactive assessment was to hit 16 targets, randomly appearing in four directions, as fast as possible. Each participant was tested twice by two different testers.

RESULTS:

Good reliability was found of neck motion kinematic measures in flexion, extension, and rotation (0.64-0.93 inter-class correlation). High reliability was shown for peak velocity globally (0.93), in left rotation (0.9), right rotation and extension (0.88), and flexion (0.86). Mean velocity had a good global reliability (0.84), except for left rotation directed movement with moderate reliability (0.68). Minimal detectable change for peak velocity ranged from 41 to 53 °/s, while mean velocity ranged from 20 to 25 °/s.

CONCLUSIONS:

The results suggest high reliability for peak and mean velocity as measured by the interactive Neck VR assessment of neck motion kinematics. VR appears to provide a reliable and more ecologically valid method of cervical motion evaluation than previous conventional methodologies.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Interfaz Usuario-Computador / Rango del Movimiento Articular / Cuello Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Spine J Asunto de la revista: ORTOPEDIA Año: 2016 Tipo del documento: Article País de afiliación: Israel

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Interfaz Usuario-Computador / Rango del Movimiento Articular / Cuello Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Spine J Asunto de la revista: ORTOPEDIA Año: 2016 Tipo del documento: Article País de afiliación: Israel
...