Can intracranial pressure be measured non-invasively bedside using a two-depth Doppler-technique?
Koskinen, Lars-Owe D; Malm, Jan; Zakelis, Rolandas; Bartusis, Laimonas; Ragauskas, Arminas; Eklund, Anders.
Afiliación
  • Koskinen LD; Department of Clinical Neuroscience, Neurosurgery and Neurology, Umeå University, Umeå, 90185, Sweden. Lars-Owe.Koskinen@umu.se.
  • Malm J; Department of Clinical Neuroscience, Neurosurgery and Neurology, Umeå University, Umeå, 90185, Sweden.
  • Zakelis R; Health Telematics Science Institute, Kaunas University of Technology, Kaunas, Lithuania.
  • Bartusis L; Health Telematics Science Institute, Kaunas University of Technology, Kaunas, Lithuania.
  • Ragauskas A; Health Telematics Science Institute, Kaunas University of Technology, Kaunas, Lithuania.
  • Eklund A; Department Radiation Sciences - Biomedical Engineering, Umeå University, Umeå, Sweden.
J Clin Monit Comput ; 31(2): 459-467, 2017 Apr.
Article en En | MEDLINE | ID: mdl-26971794
ABSTRACT
Measurement of intracranial pressure (ICP) is necessary in many neurological and neurosurgical diseases. To avoid lumbar puncture or intracranial ICP probes, non-invasive ICP techniques are becoming popular. A recently developed technology uses two-depth Doppler to compare arterial pulsations in the intra- and extra-cranial segments of the ophthalmic artery for non-invasive estimation of ICP. The aim of this study was to investigate how well non-invasively-measured ICP and invasively-measured cerebrospinal fluid (CSF) pressure correlate. We performed multiple measurements over a wide ICP span in eighteen elderly patients with communicating hydrocephalus. As a reference, an automatic CSF infusion apparatus was connected to the lumbar space. Ringer's solution was used to create elevation to pre-defined ICP levels. Bench tests of the infusion apparatus showed a random error (95 % CI) of less than ±0.9 mmHg and a systematic error of less than ±0.5 mmHg. Reliable Doppler signals were obtained in 13 (72 %) patients. An infusion test could not be performed in one patient. Thus, twelve patients and a total of 61 paired data points were studied. The correlation between invasive and non-invasive ICP measurements was good (R = 0.74), and the 95 % limits of agreements were -1.4 ± 8.8 mmHg. The within-patient correlation varied between 0.47 and 1.00. This non-invasive technique is promising, and these results encourage further development and evaluation before the method can be recommended for use in clinical practice.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arteria Oftálmica / Presión Intracraneal / Ultrasonografía Doppler Transcraneal / Ultrasonografía Doppler / Pruebas en el Punto de Atención / Hidrocéfalo Normotenso Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: J Clin Monit Comput Asunto de la revista: INFORMATICA MEDICA / MEDICINA Año: 2017 Tipo del documento: Article País de afiliación: Suecia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arteria Oftálmica / Presión Intracraneal / Ultrasonografía Doppler Transcraneal / Ultrasonografía Doppler / Pruebas en el Punto de Atención / Hidrocéfalo Normotenso Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: J Clin Monit Comput Asunto de la revista: INFORMATICA MEDICA / MEDICINA Año: 2017 Tipo del documento: Article País de afiliación: Suecia
...