BACKGROUND:
Morbidity and mortality of cervical spine (C-spine) injury in pediatric trauma patients are high, necessitating quick and accurate diagnosis. Best practices emphasize minimizing radiation exposure through decreased reliance on computed tomography (CT), instead using clinical assessment, physical examination, and alternate imaging techniques. We implemented an institutional performance improvement and patient safety (PIPS) program initiative for C-spine clearance in 2010 because of high rates of CT scans among pediatric trauma patients.METHODS:
A retrospective review of pediatric trauma patients, aged 0 years to 14 years, in the pre- and post-PIPS implementation periods was conducted. Rates of C-spine CT, overall CT, other imaging modalities, radiation exposure, patient characteristics, and injury severity were compared, and compliance with PIPS protocol was reviewed.RESULTS:
Patient characteristics and injury severity were similar before and after PIPS implementation. C-spine CT rates decreased significantly between groups (30% vs. 13%, p < 0.001), whereas C-spine plain x-ray rates increased significantly (7% vs. 25%, p < 0.001). There was no difference in C-spine magnetic resonance imaging between groups (12% vs. 10%, p = 0.11). In 2007, 71% of patients received a CT scan for any reason. However, the overall CT rate decreased significantly between groups (60% vs. 45%, p < 0.001). There was an estimated 22% decrease in lifetime attributable risk (LAR) for any cancer due to ionizing imaging exposure in males and 38% decrease in females between the pre- and post-PIPS groups. There was a 54% decrease in LAR for thyroid cancer in males and females between groups; 2014 compliance with the protocol was excellent (82-90% per quarter).CONCLUSIONS:
Performance improvement and patient safety program-generated protocol can significantly decrease ionizing radiation exposure. We demonstrate that a simple protocol focused on C-spine imaging has high compliance, decreased C-spine CT scans, and decreased LAR for thyroid cancer. A secondary benefit is a reduction in total CT imaging, with an associated decrease in LAR for all cancers. LEVEL OF EVIDENCE Therapeutic study, level IV; diagnostic study, level III.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Contexto en salud:
2_ODS3
/
6_ODS3_enfermedades_notrasmisibles
Problema de salud:
2_muertes_prevenibles
/
6_thyroid_cancer
Asunto principal:
Traumatismos Vertebrales
/
Tomografía Computarizada por Rayos X
/
Vértebras Cervicales
/
Mejoramiento de la Calidad
/
Seguridad del Paciente
Tipo de estudio:
Guideline
/
Observational_studies
/
Risk_factors_studies
Aspecto:
Implementation_research
Límite:
Adolescent
/
Child
/
Child, preschool
/
Female
/
Humans
/
Infant
/
Male
/
Newborn
Idioma:
En
Revista:
J Trauma Acute Care Surg
Año:
2016
Tipo del documento:
Article