Your browser doesn't support javascript.
loading
Whole-body radiofrequency coil for (31) P MRSI at 7 T.
Löring, J; van der Kemp, W J M; Almujayyaz, S; van Oorschot, J W M; Luijten, P R; Klomp, D W J.
Afiliación
  • Löring J; Department of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands.
  • van der Kemp WJ; Department of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands.
  • Almujayyaz S; MR Coils BV, Zaltbommel, the Netherlands.
  • van Oorschot JW; Department of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands.
  • Luijten PR; Department of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands.
  • Klomp DW; Department of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands.
NMR Biomed ; 29(6): 709-20, 2016 06.
Article en En | MEDLINE | ID: mdl-27037615
ABSTRACT
Widespread use of ultrahigh-field (31) P MRSI in clinical studies is hindered by the limited field of view and non-uniform radiofrequency (RF) field obtained from surface transceivers. The non-uniform RF field necessitates the use of high specific absorption rate (SAR)-demanding adiabatic RF pulses, limiting the signal-to-noise ratio (SNR) per unit of time. Here, we demonstrate the feasibility of using a body-sized volume RF coil at 7 T, which enables uniform excitation and ultrafast power calibration by pick-up probes. The performance of the body coil is examined by bench tests, and phantom and in vivo measurements in a 7-T MRI scanner. The accuracy of power calibration with pick-up probes is analyzed at a clinical 3-T MR system with a close to identical (1) H body coil integrated at the MR system. Finally, we demonstrate high-quality three-dimensional (31) P MRSI of the human body at 7 T within 5 min of data acquisition that includes RF power calibration. Copyright © 2016 John Wiley & Sons, Ltd.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Isótopos de Fósforo / Imagen por Resonancia Magnética / Espectroscopía de Resonancia Magnética / Compuestos de Fósforo / Imagen de Cuerpo Entero / Imagen Molecular / Magnetismo Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Humans Idioma: En Revista: NMR Biomed Asunto de la revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Año: 2016 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Isótopos de Fósforo / Imagen por Resonancia Magnética / Espectroscopía de Resonancia Magnética / Compuestos de Fósforo / Imagen de Cuerpo Entero / Imagen Molecular / Magnetismo Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Humans Idioma: En Revista: NMR Biomed Asunto de la revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Año: 2016 Tipo del documento: Article País de afiliación: Países Bajos
...