Your browser doesn't support javascript.
loading
Screening of preservatives by HPLC-PDA-ESI/MS: A focus on both allowed and recently forbidden compounds in the new EU cosmetics regulation.
Lecce, Raffaele; Regazzoni, Luca; Mustazza, Carlo; Incarnato, Giampaolo; Porrà, Rita; Panusa, Alessia.
Afiliación
  • Lecce R; Dipartimento del Farmaco, Istituto Superiore di Sanità, Viale Regina Elena 299, 00161 Rome, Italy.
  • Regazzoni L; Dipartimento di Scienze Farmaceutiche, Università degli Studi di Milano,Via Mangiagalli 25, 20133 Milan, Italy.
  • Mustazza C; Dipartimento del Farmaco, Istituto Superiore di Sanità, Viale Regina Elena 299, 00161 Rome, Italy.
  • Incarnato G; Dipartimento del Farmaco, Istituto Superiore di Sanità, Viale Regina Elena 299, 00161 Rome, Italy.
  • Porrà R; Dipartimento del Farmaco, Istituto Superiore di Sanità, Viale Regina Elena 299, 00161 Rome, Italy.
  • Panusa A; Dipartimento del Farmaco, Istituto Superiore di Sanità, Viale Regina Elena 299, 00161 Rome, Italy. Electronic address: alessia.panusa@iss.it.
J Pharm Biomed Anal ; 125: 260-9, 2016 Jun 05.
Article en En | MEDLINE | ID: mdl-27055177
Commission regulation (EU) No 358/2014 amending the new regulation (EC) No 1223/2009 on cosmetics has prohibited the use of isopropyl-, isobutyl-, phenyl-, benzyl- and pentylparaben. Furthermore, Commission regulation (EU) No 1004/2014 has lowered the maximum permitted concentration of butyl- and propylparaben in cosmetics and it has also banned them in leave-on products designed for application on the nappy area of children under three years of age. A HPLC-PDA-ESI/MS method has been developed herein for the detection of seventeen preservatives, both the most utilised and the recently forbidden by the new EU regulations. The separation of these compounds, including benzoic acid and its derivatives in a 1.10 - 3.04 log Pow range, has been performed with a gradient elution on a Symmetry(®) C18 column (250×4.6mm i.d., particle size 5µm) with water and acetonitrile (0.1% formic acid) as mobile phase. Quantification has been carried out by HPLC-PDA. The method has been validated and successfully applied to the analysis of a large number of cosmetics with different functions like rinse-off and leave-on, or composition like skin, hair, face and oral products.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cromatografía Líquida de Alta Presión / Cosméticos / Espectrometría de Masa por Ionización de Electrospray Tipo de estudio: Diagnostic_studies / Screening_studies Idioma: En Revista: J Pharm Biomed Anal Año: 2016 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cromatografía Líquida de Alta Presión / Cosméticos / Espectrometría de Masa por Ionización de Electrospray Tipo de estudio: Diagnostic_studies / Screening_studies Idioma: En Revista: J Pharm Biomed Anal Año: 2016 Tipo del documento: Article País de afiliación: Italia
...