Your browser doesn't support javascript.
loading
Electro-deposited poly-luminol molecularly imprinted polymer coating on carboxyl graphene for stir bar sorptive extraction of estrogens in milk.
Liu, Haibo; Qiao, Li; Gan, Ning; Lin, Saichai; Cao, Yuting; Hu, Futao; Wang, Jiayu; Chen, Yinji.
Afiliación
  • Liu H; Faculty of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211, China.
  • Qiao L; Faculty of Marine Science, Ningbo University, Ningbo 315211, China.
  • Gan N; Faculty of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211, China. Electronic address: ganning@nbu.edu.cn.
  • Lin S; Faculty of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211, China.
  • Cao Y; Faculty of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211, China.
  • Hu F; Faculty of Marine Science, Ningbo University, Ningbo 315211, China.
  • Wang J; Faculty of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211, China.
  • Chen Y; Department of Food Science and Engineering/Collaborative Innovation Center for Modern Grain Circulation and Safety, Nanjing University of Finance and Economics, Nanjing 210007, China.
Article en En | MEDLINE | ID: mdl-27249165
ABSTRACT
Electrochemical polymerization of luminol molecularly imprinted polymer on carboxyl graphene (MIP/CG) was developed as stir bar sorptive extraction (SBSE) coating for selective pre-concentration and specific recognition of bisphenol A (BPA), hexoestrol and diethylstilbestrol in milk samples. Luminol was employed as monomer and BPA as the template to prepare MIP under 0-0.6V electro-polymerization. Carboxyl graphene was modified on pencil lead as the substrate to increase extraction capacity. The preparation and extraction conditions affecting the extraction efficiency were optimized. Under the optimized conditions, a good linearity of three estrogens was obtained in the range of 4-1000ngmL(-1). The average recoveries at the three spiked levels of the three estrogens ranged from 83.4% to 96.3% with the relative standard deviations (RSD)≤7.1%. The limits of detection were in the range of 0.36-1.09ngmL(-1). The developed method with low cost, high selectivity and good reproducibility can be potentially applied for determining trace estrogens in complex food samples.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Polímeros / Leche / Estrógenos no Esteroides / Impresión Molecular / Análisis de los Alimentos / Luminol Tipo de estudio: Evaluation_studies Límite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2016 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Polímeros / Leche / Estrógenos no Esteroides / Impresión Molecular / Análisis de los Alimentos / Luminol Tipo de estudio: Evaluation_studies Límite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2016 Tipo del documento: Article País de afiliación: China
...