Your browser doesn't support javascript.
loading
Preparation of viral samples within biocontainment for ultrastructural analysis: Utilization of an innovative processing capsule for negative staining.
Monninger, Mitchell K; Nguessan, Chrystal A; Blancett, Candace D; Kuehl, Kathleen A; Rossi, Cynthia A; Olschner, Scott P; Williams, Priscilla L; Goodman, Steven L; Sun, Mei G.
Afiliación
  • Monninger MK; Pathology Division, United States Army Medical Research Institute of Infectious Diseases (USAMRIID), 1425 Porter Street, Fort Detrick, MD, 21702, United States.
  • Nguessan CA; Pathology Division, United States Army Medical Research Institute of Infectious Diseases (USAMRIID), 1425 Porter Street, Fort Detrick, MD, 21702, United States.
  • Blancett CD; Pathology Division, United States Army Medical Research Institute of Infectious Diseases (USAMRIID), 1425 Porter Street, Fort Detrick, MD, 21702, United States.
  • Kuehl KA; Pathology Division, United States Army Medical Research Institute of Infectious Diseases (USAMRIID), 1425 Porter Street, Fort Detrick, MD, 21702, United States.
  • Rossi CA; Diagnostic Systems Division, United States Army Medical Research Institute of Infectious Diseases (USAMRIID), 1425 Porter Street, Fort Detrick, MD, 21702, United States.
  • Olschner SP; Diagnostic Systems Division, United States Army Medical Research Institute of Infectious Diseases (USAMRIID), 1425 Porter Street, Fort Detrick, MD, 21702, United States.
  • Williams PL; Diagnostic Systems Division, United States Army Medical Research Institute of Infectious Diseases (USAMRIID), 1425 Porter Street, Fort Detrick, MD, 21702, United States.
  • Goodman SL; Microscopy Innovations LLC, Marshfield, WI, United States.
  • Sun MG; Pathology Division, United States Army Medical Research Institute of Infectious Diseases (USAMRIID), 1425 Porter Street, Fort Detrick, MD, 21702, United States. Electronic address: mei.g.sun.ctr@mail.mil.
J Virol Methods ; 238: 70-76, 2016 12.
Article en En | MEDLINE | ID: mdl-27751950
ABSTRACT
Transmission electron microscopy can be used to observe the ultrastructure of viruses and other microbial pathogens with nanometer resolution. In a transmission electron microscope (TEM), the image is created by passing an electron beam through a specimen with contrast generated by electron scattering from dense elements in the specimen. Viruses do not normally contain dense elements, so a negative stain that places dense heavy metal salts around the sample is added to create a dark border. To prepare a virus sample for a negative stain transmission electron microscopy, a virus suspension is applied to a TEM grid specimen support, which is a 3mm diameter fragile specimen screen coated with a few nanometers of plastic film. Then, deionized (dI) water rinses and a negative stain solution are applied to the grid. All infectious viruses must be handled in a biosafety cabinet (BSC) and many require a biocontainment laboratory environment. Staining viruses in biosafety levels (BSL) 3 and 4 is especially challenging because the support grids are small, fragile, and easily moved by air currents. In this study we evaluated a new device for negative staining viruses called mPrep/g capsule. It is a capsule that holds up to two TEM grids during all processing steps and for storage after staining is complete. This study reports that the mPrep/g capsule method is valid and effective to negative stain virus specimens, especially in high containment laboratory environments.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 3_ND Problema de salud: 3_chikungunya / 3_neglected_diseases Asunto principal: Manejo de Especímenes / Virus / Coloración Negativa / Contención de Riesgos Biológicos / Microscopía Electrónica de Transmisión Idioma: En Revista: J Virol Methods Año: 2016 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 3_ND Problema de salud: 3_chikungunya / 3_neglected_diseases Asunto principal: Manejo de Especímenes / Virus / Coloración Negativa / Contención de Riesgos Biológicos / Microscopía Electrónica de Transmisión Idioma: En Revista: J Virol Methods Año: 2016 Tipo del documento: Article País de afiliación: Estados Unidos
...