Evaluation of gastric blood supply in diabetic patients with gastroparesis by contrast-enhanced ultrasound.
Shen, Hao-Lin; Yang, Shu-Ping; Wang, Kang-Jian; Huang, Bei-Lei; Huang, Wen-Bao; Wu, Jin-Zhi; Lv, Guo-Rong.
Afiliación
  • Shen HL; 1 Department of Ultrasound, Zhangzhou Hospital, Fujian Medical University, Zhangzhou, Fujian, China.
  • Yang SP; 1 Department of Ultrasound, Zhangzhou Hospital, Fujian Medical University, Zhangzhou, Fujian, China.
  • Wang KJ; 1 Department of Ultrasound, Zhangzhou Hospital, Fujian Medical University, Zhangzhou, Fujian, China.
  • Huang BL; 1 Department of Ultrasound, Zhangzhou Hospital, Fujian Medical University, Zhangzhou, Fujian, China.
  • Huang WB; 2 Department of Gastroenterology, Zhangzhou Hospital, Fujian Medical University, Zhangzhou, Fujian, China.
  • Wu JZ; 3 Department of Endocrinology, Zhangzhou Hospital, Fujian Medical University, Zhangzhou, Fujian, China.
  • Lv GR; 4 Department of Ultrasound, Second Affiliated Hospital, Fujian Medical University, Quanzhou, Fujian, China.
Br J Radiol ; 89(1068): 20160366, 2016 Dec.
Article en En | MEDLINE | ID: mdl-27759430
OBJECTIVE: Improvement in regional blood flow has been shown to ameliorate diabetic gastroparesis. We compared the gastric blood supply in patients with diabetes with gastroparesis with that in healthy subjects, by using contrast-enhanced ultrasound (CEUS). METHODS: 30 healthy subjects and 40 patients with diabetic gastroparesis were enrolled. The CEUS parameters of greater curvatures of the antrum (GCOA) and lesser curvatures of the antrum (LCOA), including peak intensity (PI) and the area under the curve (AUC), were compared between the two groups. RESULTS: Intraclass correlation coefficient (ICC) for PI in healthy subjects measured on CEUS were 0.831-0.857 and 0.803-0.823, respectively. Intra-ICC and inter-ICC values for AUC were 0.805-0.823 and 0.813-0.815, respectively. In both groups, no significant difference was observed in PI and AUC values of GCOA and LCOA (p > 0.05). The PI and AUC of GCOA and LCOA in the diabetes group were less than those in the normal group (p < 0.05). CONCLUSION: CEUS can assess stomach wall vascularity with a high reproducibility. Microcirculation in the antrum of patients with diabetic gastroparesis is poorer than that of normal group, which is consistent with the mechanisms of diabetic neuropathy. CEUS can be used for evaluation of microvascular perfusion in patients with stomach wall disease. Advances in knowledge: This was the first study to use CEUS for assessment of blood supply of the gastric wall and to compare microvascular perfusion between healthy individuals and patients with diabetes with gastroparesis.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Estómago / Ultrasonografía / Gastroparesia / Medios de Contraste / Complicaciones de la Diabetes Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Br J Radiol Año: 2016 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Estómago / Ultrasonografía / Gastroparesia / Medios de Contraste / Complicaciones de la Diabetes Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Br J Radiol Año: 2016 Tipo del documento: Article País de afiliación: China
...