Your browser doesn't support javascript.
loading
A calcified polymeric valve for valve-in-valve applications.
Falahatpisheh, Ahmad; Morisawa, Daisuke; Toosky, Taraz T; Kheradvar, Arash.
Afiliación
  • Falahatpisheh A; The Edwards Lifesciences Center for Advanced Cardiovascular Technology, University of California Irvine, Irvine, CA 92697, USA.
  • Morisawa D; The Edwards Lifesciences Center for Advanced Cardiovascular Technology, University of California Irvine, Irvine, CA 92697, USA.
  • Toosky TT; Toosky Engineering Models Inc., 2650 Walnut Ave # N, Tustin, CA 92780, USA.
  • Kheradvar A; The Edwards Lifesciences Center for Advanced Cardiovascular Technology, University of California Irvine, Irvine, CA 92697, USA. Electronic address: arashkh@uci.edu.
J Biomech ; 50: 77-82, 2017 01 04.
Article en En | MEDLINE | ID: mdl-27887725
The prevalence of aortic valve stenosis (AS) is increasing in the aging society. More recently, novel treatments and devices for AS, especially transcatheter aortic valve replacement (TAVR) have significantly changed the therapeutic approach to this disease. Research and development related to TAVR require testing these devices in the calcified heart valves that closely mimic a native calcific valve. However, no animal model of AS has yet been available. Alternatively, animals with normal aortic valve that are currently used for TAVR experiments do not closely replicate the aortic valve pathology required for proper testing of these devices. To solve this limitation, for the first time, we developed a novel polymeric valve whose leaflets possess calcium hydroxyapatite inclusions immersed in them. This study reports the characteristics and feasibility of these valves. Two types of the polymeric valve, i.e., moderate and severe calcified AS models were developed and tested by deploying a transcatheter valve in those and measuring the related hemodynamics. The valves were tested in a heart flow simulator, and were studied using echocardiography. Our results showed high echogenicity of the polymeric valve, that was correlated to the severity of the calcification. Aortic valve area of the polymeric valves was measured, and the severity of stenosis was defined according to the clinical guidelines. Accordingly, we showed that these novel polymeric valves closely mimic AS, and can be a desired cost-saving solution for testing the performance of the transcatheter aortic valve systems in vitro.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Calcinosis Tipo de estudio: Guideline / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: J Biomech Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Calcinosis Tipo de estudio: Guideline / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: J Biomech Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos
...