Your browser doesn't support javascript.
loading
QD-Biopolymer-TSPP Assembly as Efficient BiFRET Sensor for Ratiometric and Visual Detection of Zinc Ion.
Liu, Yuqian; Qu, Xiaojun; Guo, Qingsheng; Sun, Qingjiang; Huang, Xuebin.
Afiliación
  • Liu Y; State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University , Nanjing 210096, P. R. China.
  • Qu X; State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University , Nanjing 210096, P. R. China.
  • Guo Q; State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University , Nanjing 210096, P. R. China.
  • Sun Q; State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University , Nanjing 210096, P. R. China.
  • Huang X; School of Chemistry and Chemical Engineering, Beijing Institute of Technology , Beijing 100081, P. R. China.
ACS Appl Mater Interfaces ; 9(5): 4725-4732, 2017 Feb 08.
Article en En | MEDLINE | ID: mdl-28084719
ABSTRACT
In this work, we report a new type of quantum dot (QD)-based fluorescence resonance energy transfer (FRET) assembly and its utility for sensing Zn2+ in different media. The assembly on the QD scaffold is via first coating of poly(dA) homopolymer/double-stranded DNA, followed by loading of meso-tetra(4-sulfonatophenyl)porphine dihydrochloride (TSPP), both of which are electrostatic, offering the advantages of cost-efficiency and simplicity. More importantly, the biopolymer coating minimizes the interfacial thickness to be ≤2 nm for QD-TSPP FRET, which results in improvements of up to 60-fold for single FRET efficiency and nearly 4-fold for total FRET efficiency of the QD-biopolymer-TSPP assemblies in comparison with silica-coating-based QD-TSPP assemblies. On the basis of Zn2+-chelation-induced spectral modulation, dual-emission QD-poly(dA)-TSPP assemblies are developed as a ratiometric Zn2+ sensor with increased sensitivity and specificity. The sensor either in solution or on a paper substrate displays continuous color changes from yellow to bright green toward Zn2+, exhibiting excellent visualization capability. By utilizing the competitive displacement of Zn2+, the sensor is also demonstrated to have good reversibility. Furthermore, the sensor is successfully used to visualize exogenous Zn2+ in living cells. Together the QD-biopolymer-TSPP assembly provides an inexpensive, sensitive, and reliable sensing platform not only for on-site analytical applications but also for high-resolution cellular imaging.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: ACS Appl Mater Interfaces Asunto de la revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Año: 2017 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: ACS Appl Mater Interfaces Asunto de la revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Año: 2017 Tipo del documento: Article
...