VirtoScan - a mobile, low-cost photogrammetry setup for fast post-mortem 3D full-body documentations in x-ray computed tomography and autopsy suites.
Kottner, Sören; Ebert, Lars C; Ampanozi, Garyfalia; Braun, Marcel; Thali, Michael J; Gascho, Dominic.
Afiliación
  • Kottner S; Zurich Institute of Forensic Medicine, University of Zurich, Winterthurerstrasse 190/52, 8057, Zürich, Switzerland. soeren.kottner@irm.uzh.ch.
  • Ebert LC; Zurich Institute of Forensic Medicine, University of Zurich, Winterthurerstrasse 190/52, 8057, Zürich, Switzerland.
  • Ampanozi G; Zurich Institute of Forensic Medicine, University of Zurich, Winterthurerstrasse 190/52, 8057, Zürich, Switzerland.
  • Braun M; Forensic Science Institute, Zeughausstrasse 11, 8004, Zurich, Switzerland.
  • Thali MJ; Zurich Institute of Forensic Medicine, University of Zurich, Winterthurerstrasse 190/52, 8057, Zürich, Switzerland.
  • Gascho D; Zurich Institute of Forensic Medicine, University of Zurich, Winterthurerstrasse 190/52, 8057, Zürich, Switzerland.
Forensic Sci Med Pathol ; 13(1): 34-43, 2017 Mar.
Article en En | MEDLINE | ID: mdl-28144846
Injuries such as bite marks or boot prints can leave distinct patterns on the body's surface and can be used for 3D reconstructions. Although various systems for 3D surface imaging have been introduced in the forensic field, most techniques are both cost-intensive and time-consuming. In this article, we present the VirtoScan, a mobile, multi-camera rig based on close-range photogrammetry. The system can be integrated into automated PMCT scanning procedures or used manually together with lifting carts, autopsy tables and examination couch. The VirtoScan is based on a moveable frame that carries 7 digital single-lens reflex cameras. A remote control is attached to each camera and allows the simultaneous triggering of the shutter release of all cameras. Data acquisition in combination with the PMCT scanning procedures took 3:34 min for the 3D surface documentation of one side of the body compared to 20:20 min of acquisition time when using our in-house standard. A surface model comparison between the high resolution output from our in-house standard and a high resolution model from the multi-camera rig showed a mean surface deviation of 0.36 mm for the whole body scan and 0.13 mm for a second comparison of a detailed section of the scan. The use of the multi-camera rig reduces the acquisition time for whole-body surface documentations in medico-legal examinations and provides a low-cost 3D surface scanning alternative for forensic investigations.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 Problema de salud: 1_financiamento_saude Asunto principal: Fotogrametría / Tomografía Computarizada por Rayos X / Imagenología Tridimensional / Patologia Forense / Imagen de Cuerpo Entero Tipo de estudio: Health_economic_evaluation Límite: Humans Idioma: En Revista: Forensic Sci Med Pathol Asunto de la revista: JURISPRUDENCIA / MEDICINA / PATOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 1_ASSA2030 Problema de salud: 1_financiamento_saude Asunto principal: Fotogrametría / Tomografía Computarizada por Rayos X / Imagenología Tridimensional / Patologia Forense / Imagen de Cuerpo Entero Tipo de estudio: Health_economic_evaluation Límite: Humans Idioma: En Revista: Forensic Sci Med Pathol Asunto de la revista: JURISPRUDENCIA / MEDICINA / PATOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Suiza
...