Your browser doesn't support javascript.
loading
Preclinical endoscopic training using a part-task simulator: learning curve assessment and determination of threshold score for advancement to clinical endoscopy.
Jirapinyo, Pichamol; Abidi, Wasif M; Aihara, Hiroyuki; Zaki, Theodore; Tsay, Cynthia; Imaeda, Avlin B; Thompson, Christopher C.
Afiliación
  • Jirapinyo P; Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital, 75 Francis Street, Boston, MA, 02115, USA.
  • Abidi WM; Harvard Medical School, Boston, MA, USA.
  • Aihara H; Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital, 75 Francis Street, Boston, MA, 02115, USA.
  • Zaki T; Harvard Medical School, Boston, MA, USA.
  • Tsay C; Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital, 75 Francis Street, Boston, MA, 02115, USA.
  • Imaeda AB; Harvard Medical School, Boston, MA, USA.
  • Thompson CC; Yale University School of Medicine, New Haven, CT, USA.
Surg Endosc ; 31(10): 4010-4015, 2017 10.
Article en En | MEDLINE | ID: mdl-28229238
ABSTRACT

BACKGROUND:

Preclinical simulator training has the potential to decrease endoscopic procedure time and patient discomfort. This study aims to characterize the learning curve of endoscopic novices in a part-task simulator and propose a threshold score for advancement to initial clinical cases.

METHODS:

Twenty novices with no prior endoscopic experience underwent repeated endoscopic simulator sessions using the part-task simulator. Simulator scores were collected; their inverse was averaged and fit to an exponential curve. The incremental improvement after each session was calculated. Plateau was defined as the session after which incremental improvement in simulator score model was less than 5%. Additionally, all participants filled out questionnaires regarding simulator experience after sessions 1, 5, 10, 15, and 20. A visual analog scale and NASA task load index were used to assess levels of comfort and demand.

RESULTS:

Twenty novices underwent 400 simulator sessions. Mean simulator scores at sessions 1, 5, 10, 15, and 20 were 78.5 ± 5.95, 176.5 ± 17.7, 275.55 ± 23.56, 347 ± 26.49, and 441.11 ± 38.14. The best fit exponential model was [time/score] = 26.1 × [session #]-0.615; r 2 = 0.99. This corresponded to an incremental improvement in score of 35% after the first session, 22% after the second, 16% after the third and so on. Incremental improvement dropped below 5% after the 12th session corresponding to the predicted score of 265. Simulator training was related to higher comfort maneuvering an endoscope and increased readiness for supervised clinical endoscopy, both plateauing between sessions 10 and 15. Mental demand, physical demand, and frustration levels decreased with increased simulator training.

CONCLUSION:

Preclinical training using an endoscopic part-task simulator appears to increase comfort level and decrease mental and physical demand associated with endoscopy. Based on a rigorous model, we recommend that novices complete a minimum of 12 training sessions and obtain a simulator score of at least 265 to be best prepared for clinical endoscopy.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Competencia Clínica / Endoscopía / Entrenamiento Simulado Tipo de estudio: Prognostic_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Surg Endosc Asunto de la revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Competencia Clínica / Endoscopía / Entrenamiento Simulado Tipo de estudio: Prognostic_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Surg Endosc Asunto de la revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos
...