Feasibility of Rapid Linear-Endocardial and Epicardial Ventricular Ablation Using an Irrigated Multipolar Radiofrequency Ablation Catheter.
Nazer, Babak; Walters, Tomos E; Duggirala, Srikant; Gerstenfeld, Edward P.
Afiliación
  • Nazer B; From the Electrophysiology Section, Division of Cardiology, Department of Medicine, University of California San Francisco.
  • Walters TE; From the Electrophysiology Section, Division of Cardiology, Department of Medicine, University of California San Francisco.
  • Duggirala S; From the Electrophysiology Section, Division of Cardiology, Department of Medicine, University of California San Francisco.
  • Gerstenfeld EP; From the Electrophysiology Section, Division of Cardiology, Department of Medicine, University of California San Francisco. egerstenfeld@medicine.ucsf.edu.
Article en En | MEDLINE | ID: mdl-28288961
BACKGROUND: A common strategy for ablation of scar-based ventricular tachycardia is delivering multiple lesions in a linear pattern. METHODS AND RESULTS: We tested the efficacy of a novel linear irrigated multipolar ablation catheter capable of creating linear lesions with a single application. Healthy swine underwent endocardial and epicardial linear ablation using a novel linear irrigated ablation catheter; control animals underwent focal lesions in a linear pattern over 3.5 cm with an irrigated radiofrequency catheter. The linear catheter contained 7 irrigated electrodes spaced over 3.5 cm and could deliver ≤25 W to each electrode. Linear ablation required significantly less radiofrequency time than focal ablation (56±11 versus 497±110 seconds; P<0.0001). At gross pathology, linear (n=18) epicardial lines were longer than focal (n=8) epicardial lines (3.3±0.7 versus 2.1±0.9 cm; P<0.0005), with greater volume (3.8±2.9 versus 1.5±1.6 cm3; P=0.002). There was no difference between linear (n=22) and focal (n=7) endocardial line length or volume. Gaps (length 2.8±0.9 mm) were present in 53% of focal lines and 0% of linear ablation lines. No perforations, steam pops, or thrombus were noted. CONCLUSIONS: Compared with sequential focal radiofrequency ablation in a linear pattern, an irrigated multipolar linear ablation catheter safely delivers contiguous endocardial or epicardial lesions without gaps in a single ablation. This catheter shows promise for decreasing ventricular tachycardia ablation procedure time and improving outcome.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Taquicardia Ventricular / Ablación por Catéter / Catéteres Cardíacos / Ventrículos Cardíacos Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals Idioma: En Revista: Circ Arrhythm Electrophysiol Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2017 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Taquicardia Ventricular / Ablación por Catéter / Catéteres Cardíacos / Ventrículos Cardíacos Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals Idioma: En Revista: Circ Arrhythm Electrophysiol Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA Año: 2017 Tipo del documento: Article
...