Rapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system.
Yamaguchi, Nobuyasu; Tokunaga, Yusuke; Goto, Satoko; Fujii, Yudai; Banno, Fumiya; Edagawa, Akiko.
Afiliación
  • Yamaguchi N; Osaka Institute of Public Health, 1-3-69 Nakamichi, Higashinari, Osaka, 537-0025, Japan. nyyamaguchi@iph.osaka.jp.
  • Tokunaga Y; Graduate School of Pharmaceutical Sciences, Osaka University, 1-6 Yamada-oka, Suita, Osaka, 565-0871, Japan. nyyamaguchi@iph.osaka.jp.
  • Goto S; Osaka Institute of Public Health, 1-3-69 Nakamichi, Higashinari, Osaka, 537-0025, Japan.
  • Fujii Y; Graduate School of Pharmaceutical Sciences, Osaka University, 1-6 Yamada-oka, Suita, Osaka, 565-0871, Japan.
  • Banno F; Graduate School of Pharmaceutical Sciences, Osaka University, 1-6 Yamada-oka, Suita, Osaka, 565-0871, Japan.
  • Edagawa A; Graduate School of Pharmaceutical Sciences, Osaka University, 1-6 Yamada-oka, Suita, Osaka, 565-0871, Japan.
Sci Rep ; 7(1): 3092, 2017 06 08.
Article en En | MEDLINE | ID: mdl-28596545
ABSTRACT
Legionnaires' disease, predominantly caused by the bacterium Legionella pneumophila, has increased in prevalence worldwide. The most common mode of transmission of Legionella is inhalation of contaminated aerosols, such as those generated by cooling towers. Simple, rapid and accurate methods to enumerate L. pneumophila are required to prevent the spread of this organism. Here, we applied a microfluidic device for on-chip fluorescent staining and semi-automated counting of L. pneumophila in cooling tower water. We also constructed a portable system for rapid on-site monitoring and used it to enumerate target bacterial cells rapidly flowing in the microchannel. A fluorescently-labelled polyclonal antibody was used for the selective detection of L. pneumophila serogroup 1 in the samples. The counts of L. pneumophila in cooling tower water obtained using the system and fluorescence microscopy were similar. The detection limit of the system was 104 cells/ml, but lower numbers of L. pneumophila cells (101 to 103 cells/ml) could be detected following concentration of 0.5-3 L of the water sample by filtration. Our technique is rapid to perform (1.5 h), semi-automated (on-chip staining and counting), and portable for on-site measurement, and it may therefore be effective in the initial screening of Legionella contamination in freshwater.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 2_ODS3 Problema de salud: 2_quimicos_contaminacion Asunto principal: Microbiología del Agua / Gammaproteobacteria / Microfluídica Tipo de estudio: Risk_factors_studies Idioma: En Revista: Sci Rep Año: 2017 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 2_ODS3 Problema de salud: 2_quimicos_contaminacion Asunto principal: Microbiología del Agua / Gammaproteobacteria / Microfluídica Tipo de estudio: Risk_factors_studies Idioma: En Revista: Sci Rep Año: 2017 Tipo del documento: Article País de afiliación: Japón
...