Your browser doesn't support javascript.
loading
Efficacy, Safety, and Risk Factors for Failure of Standalone Ab Interno Gelatin Microstent Implantation versus Standalone Trabeculectomy.
Schlenker, Matthew B; Gulamhusein, Husayn; Conrad-Hengerer, Ina; Somers, Alix; Lenzhofer, Markus; Stalmans, Ingeborg; Reitsamer, Herbert; Hengerer, Fritz H; Ahmed, Iqbal Ike K.
Afiliación
  • Schlenker MB; Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Canada. Electronic address: matt.schlenker@utoronto.ca.
  • Gulamhusein H; Department of Medicine, McMaster University, Hamilton, Ontario, Canada.
  • Conrad-Hengerer I; Center for Vision Science, Ruhr University Eye Hospital, Bochum, Germany.
  • Somers A; Department of Ophthalmology, University Hospitals UZ Leuven, Leuven, Belgium.
  • Lenzhofer M; Department of Ophthalmology and Optometry, Paracelsus Medical University Salzburg, Salzburg, Austria.
  • Stalmans I; Department of Ophthalmology, University Hospitals UZ Leuven, Leuven, Belgium.
  • Reitsamer H; Department of Ophthalmology and Optometry, Paracelsus Medical University Salzburg, Salzburg, Austria.
  • Hengerer FH; University Eye Clinic, Frankfurt, Germany; University Eye Clinic, Heidelberg, Germany.
  • Ahmed IIK; Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Canada.
Ophthalmology ; 124(11): 1579-1588, 2017 11.
Article en En | MEDLINE | ID: mdl-28601250
ABSTRACT

PURPOSE:

To compare the efficacy, safety, and risk factors for failure of standalone ab interno gelatin microstent implantation with mitomycin C (MMC) versus trabeculectomy with MMC.

DESIGN:

International, multicenter, retrospective interventional cohort study.

PARTICIPANTS:

Three hundred fifty-four eyes of 293 patients (185 microstent and 169 trabeculectomy) with no prior incisional surgery.

METHODS:

Consecutive eyes with uncontrolled glaucoma underwent microstent or trabeculectomy surgery from January 1, 2011 through July 31, 2015 at 4 academic ophthalmology centers Toronto, Canada; Frankfurt, Germany; Salzburg, Austria; and Leuven, Belgium. MAIN OUTCOME

MEASURES:

Primary outcome measure was hazard ratio (HR) of failure, with failure defined as 2 consecutive intraocular pressure (IOP) readings of <6 mmHg with vision loss or >17 mmHg without glaucoma medications (complete success) at least 1 month after surgery despite in-clinic interventions (including needling). Secondary outcome measures included IOP thresholds of 6 to 14 mmHg and 6 to 21 mmHg and same thresholds allowing for medications (qualified success), interventions, complications, and reoperations.

RESULTS:

Baseline characteristics were similar, except more men (56% vs. 43%), younger patients (average, by 3 years), better preoperative visual acuity (22% vs. 32% with 0.4 logarithm of the minimum angle of resolution vision or worse), and more trabeculoplasty (52% vs. 30%) among microstent eyes. The adjusted HR of failure of the microstent relative to trabeculectomy was 1.2 (95% confidence interval [CI], 0.7-2.0) for complete success and 1.3 (95% CI, 0.6-2.8) for qualified success, and similar for other outcomes. Time to 25% failure was 11.2 months (95% CI, 6.9-16.1 months) and 10.6 months (95% CI, 6.8-16.2 months) for complete success and 30.3 months (95% CI, 19.0-∞ months) and 33.3 months (95% CI, 25.7-46.2 months) for qualified success. Overall, white ethnicity was associated with decreased risk of failure (adjusted HR, 0.49; 95% CI, 0.25-0.96), and diabetes was associated with increased risk of failure (adjusted HR, 4.21; 95% CI, 2.10-8.45). There were 117 and 165 distinct

interventions:

43% and 31% underwent needling, respectively, and 50% of trabeculectomy eyes underwent laser suture lysis. There were 22 and 30 distinct complications, although most were transient. Ten percent and 5% underwent reoperation (P = 0.11).

CONCLUSIONS:

There was no detectable difference in risk of failure and safety profiles between standalone ab interno microstent with MMC and trabeculectomy with MMC.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Falla de Prótesis / Trabeculectomía / Glaucoma / Mitomicina / Implantes de Drenaje de Glaucoma / Alquilantes / Gelatina Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ophthalmology Año: 2017 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Falla de Prótesis / Trabeculectomía / Glaucoma / Mitomicina / Implantes de Drenaje de Glaucoma / Alquilantes / Gelatina Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ophthalmology Año: 2017 Tipo del documento: Article
...