Your browser doesn't support javascript.
loading
Simultaneous quantitative analysis of polyethylene glycol (PEG), PEGylated paclitaxel and paclitaxel in rats by MS/MSALL technique with hybrid quadrupole time-of-flight mass spectrometry.
Sun, Heping; Zhang, Qi; Zhang, Zhi; Tong, Jin; Chu, Dafeng; Gu, Jingkai.
Afiliación
  • Sun H; School of Life Sciences, Jilin University, Changchun 130012, PR China.
  • Zhang Q; School of Life Sciences, Jilin University, Changchun 130012, PR China.
  • Zhang Z; School of Life Sciences, Jilin University, Changchun 130012, PR China.
  • Tong J; School of Life Sciences, Jilin University, Changchun 130012, PR China.
  • Chu D; Department of Pharmaceutical Sciences, College of Pharmacy, Washington State University, Spokane, WA 99210, United States. Electronic address: chudafeng@gmail.com.
  • Gu J; School of Life Sciences, Jilin University, Changchun 130012, PR China; Clinical Pharmacology Center, Research Institute of Translational Medicine, The First Hospital of Jilin University, Changchun 130061, PR China. Electronic address: gujk@jlu.edu.cn.
J Pharm Biomed Anal ; 145: 255-261, 2017 Oct 25.
Article en En | MEDLINE | ID: mdl-28688270
ABSTRACT
PEGylation is practically one of most important modifications of drugs including small molecules, peptides and proteins, which has been proven to dramatically improve physicochemical properties and pharmacokinetic behavior of the PEGylated drugs. However, it is a challenge currently to quantitatively analyze PEG and PEGylated drugs by various analytical methods, even mass spectrometry because of multiple parent ion distribution of PEG caused by its polydispersity of molecular weight. Here we developed a robust method with MS/MSALL technique using electrospray ionization (ESI) source coupled high resolution Quadrupole Time-of-Flight (Q-TOF) mass spectrometry for the quantification of PEG2K-Paclitaxel (PEG-PTX) and its two metabolites, PEG and Paclitaxel (PTX). The analysis was performed on a 300SB-C18 column with acetonitrile and 0.1% formic acid as the mobile phase. Samples were simply prepared by protein precipitation in a small quantity of plasma (50µL). Calibration curve was linear within the range of 50.0-4000ng/mL for PEG and PEG-PTX and 1.0-1000ng/mL for PTX. The intra- and inter-day precisions were 3.2-6.9% and 3.1-6.9% for PEG, 4.1-7.8% and 4.0-9.9% for PEG-PTX, and 3.3-4.8% and 3.1-6.9% for PTX, respectively. The recoveries were greater than 90% with low matrix effects. Afterwards, the newly developed method was successfully applied to support a preclinical pharmacokinetic study in six rats after single intravenous injection of PEG-PTX (51.7mg/kg).
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Paclitaxel Límite: Animals Idioma: En Revista: J Pharm Biomed Anal Año: 2017 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Paclitaxel Límite: Animals Idioma: En Revista: J Pharm Biomed Anal Año: 2017 Tipo del documento: Article
...