Polyethylene imine/graphene oxide layer-by-layer surface functionalization for significantly improved limit of detection and binding kinetics of immunoassays on acrylate surfaces.
Miyazaki, Celina M; Mishra, Rohit; Kinahan, David J; Ferreira, Marystela; Ducrée, Jens.
Afiliación
  • Miyazaki CM; National Centre for Sensor Research, School of Physical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland; Universidade Federal de São Carlos, CCTS, Rod. João Leme dos Santos, km 110, CEP 18052-780, Sorocaba, São Paulo, Brazil. Electronic address: celinamiyazaki@ufscar.br.
  • Mishra R; National Centre for Sensor Research, School of Physical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland.
  • Kinahan DJ; National Centre for Sensor Research, School of Physical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland.
  • Ferreira M; Universidade Federal de São Carlos, CCTS, Rod. João Leme dos Santos, km 110, CEP 18052-780, Sorocaba, São Paulo, Brazil.
  • Ducrée J; National Centre for Sensor Research, School of Physical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland. Electronic address: jens.ducree@dcu.ie.
Colloids Surf B Biointerfaces ; 158: 167-174, 2017 Oct 01.
Article en En | MEDLINE | ID: mdl-28689099
ABSTRACT
Antibody immobilization on polymeric substrates is a key manufacturing step for microfluidic devices that implement sample-to-answer automation of immunoassays. In this work, a simple and versatile method to bio-functionalize poly(methylmethacrylate) (PMMA), a common material of such "Lab-on-a-Chip" systems, is proposed; using the Layer-by-Layer (LbL) technique, we assemble nanostructured thin films of poly(ethylene imine) (PEI) and graphene oxide (GO). The wettability of PMMA surfaces was significantly augmented by the surface treatment with (PEI/GO)5 film, with an 81% reduction of the contact angle, while the surface roughness increased by 600%, thus clearly enhancing wettability and antibody binding capacity. When applied to enzyme-linked immunosorbent assays (ELISAs), the limit of detection of PMMA surface was notably improved from 340pgmL-1 on commercial grade polystyrene (PS) and 230pgmL-1 on plain PMMA surfaces to 130pgmL-1 on (PEI/GO)5 treated PMMA. Furthermore, the accelerated antibody adsorption kinetics on the LbL films of GO allowed to substantially shorten incubation times, e.g. for anti-rat IgG adsorption from 2h down to 15min on conventional and treated surfaces, respectively.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Polietileneimina / Grafito Tipo de estudio: Diagnostic_studies Idioma: En Revista: Colloids Surf B Biointerfaces Asunto de la revista: QUIMICA Año: 2017 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Polietileneimina / Grafito Tipo de estudio: Diagnostic_studies Idioma: En Revista: Colloids Surf B Biointerfaces Asunto de la revista: QUIMICA Año: 2017 Tipo del documento: Article
...