Your browser doesn't support javascript.
loading
Detection of Methanol with Fast Response by Monodispersed Indium Tungsten Oxide Ellipsoidal Nanospheres.
Wang, Chong; Kou, Xueying; Xie, Ning; Guo, Lanlan; Sun, Yanfeng; Chuai, Xiaohong; Ma, Jian; Sun, Peng; Wang, Yue; Lu, Geyu.
Afiliación
  • Wang C; State Key Laboratory of Automotive Simulation and Control, Jilin University , 5988 Renmin Avenue, Changchun 130012, China.
  • Kou X; State Key Laboratory of Automotive Simulation and Control, Jilin University , 5988 Renmin Avenue, Changchun 130012, China.
  • Xie N; State Key Laboratory of Automotive Simulation and Control, Jilin University , 5988 Renmin Avenue, Changchun 130012, China.
  • Guo L; State Key Laboratory of Automotive Simulation and Control, Jilin University , 5988 Renmin Avenue, Changchun 130012, China.
  • Sun Y; State Key Laboratory of Automotive Simulation and Control, Jilin University , 5988 Renmin Avenue, Changchun 130012, China.
  • Chuai X; State Key Laboratory of Automotive Simulation and Control, Jilin University , 5988 Renmin Avenue, Changchun 130012, China.
  • Ma J; State Key Laboratory of Automotive Simulation and Control, Jilin University , 5988 Renmin Avenue, Changchun 130012, China.
  • Sun P; State Key Laboratory of Automotive Simulation and Control, Jilin University , 5988 Renmin Avenue, Changchun 130012, China.
  • Lu G; State Key Laboratory of Automotive Simulation and Control, Jilin University , 5988 Renmin Avenue, Changchun 130012, China.
ACS Sens ; 2(5): 648-654, 2017 May 26.
Article en En | MEDLINE | ID: mdl-28723171
ABSTRACT
Indium tungsten oxide ellipsoidal nanospheres were prepared with different In/W ratios by using a simple hydrothermal method without any surfactant for the first time. Sensors based on different In/W ratios samples were fabricated, and one of the samples exhibited better response to methanol compared with others. High content of defective oxygen (Ov) and proper output proportion of In to W might be the main reasons for the better gas sensing properties. The length of the nanosphere was about 150-200 nm, and the width was about 100 nm. Various techniques were applied to investigate the nanospheres. Sensing characteristics toward methanol were investigated. Significantly, the sensor exhibited ultrafast response to methanol. The response time to 400 ppm methanol was no more than 2 s and the recovery time was 9 s at 312 °C. Most importantly, the humidity almost had no effect on the response of the sensor fabricated here, which is hard to achieve in gas-sensing applications.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: ACS Sens Año: 2017 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: ACS Sens Año: 2017 Tipo del documento: Article País de afiliación: China
...