Optimization and application of octadecyl-modified monolithic silica for solid-phase extraction of drugs in whole blood samples.
Namera, Akira; Saito, Takeshi; Ota, Shigenori; Miyazaki, Shota; Oikawa, Hiroshi; Murata, Kazuhiro; Nagao, Masataka.
Afiliación
  • Namera A; Department of Forensic Medicine, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan. Electronic address: namera@hiroshima-u.ac.jp.
  • Saito T; Department of Emergency and Critical Care Medicine, Tokai University School of Medicine, Kanagawa, Japan.
  • Ota S; GL Sciences Inc., Saitama, Japan.
  • Miyazaki S; GL Sciences Inc., Saitama, Japan.
  • Oikawa H; GL Sciences Inc., Saitama, Japan.
  • Murata K; Department of Forensic Medicine, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
  • Nagao M; Department of Forensic Medicine, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
J Chromatogr A ; 1517: 9-17, 2017 Sep 29.
Article en En | MEDLINE | ID: mdl-28847585
ABSTRACT
Monolithic silica in MonoSpin for solid-phase extraction of drugs from whole blood samples was developed to facilitate high-throughput analysis. Monolithic silica of various pore sizes and octadecyl contents were synthesized, and their effects on recovery rates were evaluated. The silica monolith M18-200 (20µm through-pore size, 10.4nm mesopore size, and 17.3% carbon content) achieved the best recovery of the target analytes in whole blood samples. The extraction proceeded with centrifugal force at 1000rpm for 2min, and the eluate was directly injected into the liquid chromatography-mass spectrometry system without any tedious steps such as evaporation of extraction solvents. Under the optimized condition, low detection limits of 0.5-2.0ngmL-1 and calibration ranges up to 1000ngmL-1 were obtained. The recoveries of the target drugs in the whole blood were 76-108% with relative standard deviation of less than 14.3%. These results indicate that the developed method based on monolithic silica is convenient, highly efficient, and applicable for detecting drugs in whole blood samples.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Análisis Químico de la Sangre / Preparaciones Farmacéuticas / Dióxido de Silicio / Extracción en Fase Sólida Límite: Humans Idioma: En Revista: J Chromatogr A Año: 2017 Tipo del documento: Article