Your browser doesn't support javascript.
loading
How stable are quantitative sensory testing measurements over time? Report on 10-week reliability and agreement of results in healthy volunteers.
Nothnagel, Helen; Puta, Christian; Lehmann, Thomas; Baumbach, Philipp; Menard, Martha B; Gabriel, Brunhild; Gabriel, Holger H W; Weiss, Thomas; Musial, Frauke.
Afiliación
  • Nothnagel H; Department of Sports Medicine and Health Promotion, Friedrich Schiller University, Jena, Germany.
  • Puta C; Department of Community Medicine, National Research Center in Complementary and Alternative Medicine, UiT, The Arctic University of Norway, Tromsø, Norway.
  • Lehmann T; Department of Sports Medicine and Health Promotion, Friedrich Schiller University, Jena, Germany.
  • Baumbach P; Center for Interdisciplinary Prevention of Diseases Related to Professional Activities.
  • Menard MB; Department of Medical Statistics, Computer Sciences and Documentation, Friedrich Schiller University.
  • Gabriel B; Department of Anesthesiology and Intensive Care Medicine, University Hospital Jena, Germany.
  • Gabriel HHW; Crocker Institute, Kiawah Island, SC.
  • Weiss T; School of Integrative Medicine and Health Sciences, Saybrook University, Oakland, CA, USA.
  • Musial F; Department of Sports Medicine and Health Promotion, Friedrich Schiller University, Jena, Germany.
J Pain Res ; 10: 2067-2078, 2017.
Article en En | MEDLINE | ID: mdl-28919806
ABSTRACT

BACKGROUND:

Quantitative sensory testing (QST) is a diagnostic tool for the assessment of the somatosensory system. To establish QST as an outcome measure for clinical trials, the question of how similar the measurements are over time is crucial. Therefore, long-term reliability and limits of agreement of the standardized QST protocol of the German Research Network on Neuropathic Pain were tested.

METHODS:

QST on the lower back and hand dorsum (dominant hand) were assessed twice in 22 healthy volunteers (10 males and 12 females; mean age 46.6±13.0 years), with sessions separated by 10.0±2.9 weeks. All measurements were performed by one investigator. To investigate long-term reliability and agreement of QST, differences between the two measurements, correlation coefficients, intraclass correlation coefficients (ICCs), Bland-Altman plots (limits of agreement), and standard error of measurement were used.

RESULTS:

Most parameters of the QST were reliable over 10 weeks in healthy volunteers Almost-perfect ICCs were observed for heat pain threshold (hand) and mechanical pain sensitivity (back). Substantial ICCs were observed for heat pain threshold (back), pressure pain threshold (back), mechanical pain sensitivity (hand), and vibration detection threshold (back and hand). Some QST parameters, such as cold detection threshold, exhibited low ICCs, but also very low variability. Generally, QST measures exhibited narrow limits of agreement in the Bland-Altman plots.

CONCLUSION:

The standardized QST protocol of the German Research Network on Neuropathic Pain is feasible to be used in treatment trials. Moreover, defining a statistically meaningful change is possible, which is a prerequisite for the use of QST in clinical trials as well as in long-term investigations of disease progression.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Guideline Idioma: En Revista: J Pain Res Año: 2017 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Guideline Idioma: En Revista: J Pain Res Año: 2017 Tipo del documento: Article País de afiliación: Alemania
...