Your browser doesn't support javascript.
loading
Application of pressure-derived myocardial fractional flow reserve in chronic hemodialysis patients.
Hirose, Kimihiko; Chikamori, Taishiro; Hida, Satoshi; Tanaka, Nobuhiro; Yamashita, Jun; Igarashi, Yuko; Saitoh, Tetsushi; Tanaka, Hirokazu; Yamashina, Akira.
Afiliación
  • Hirose K; Department of Cardiology, Tokyo Medical University, Tokyo, Japan.
  • Chikamori T; Department of Cardiology, Tokyo Medical University, Tokyo, Japan. Electronic address: chikamd@tokyo-med.ac.jp.
  • Hida S; Department of Cardiology, Tokyo Medical University, Tokyo, Japan.
  • Tanaka N; Department of Cardiology, Tokyo Medical University Hachioji Medical Center, Tokyo, Japan.
  • Yamashita J; Department of Cardiology, Tokyo Medical University, Tokyo, Japan.
  • Igarashi Y; Department of Cardiology, Tokyo Medical University, Tokyo, Japan.
  • Saitoh T; Department of Cardiology, Tokyo Medical University, Tokyo, Japan.
  • Tanaka H; Department of Cardiology, Tokyo Medical University Ibaraki Medical Center, Tokyo, Japan.
  • Yamashina A; Department of Cardiology, Tokyo Medical University, Tokyo, Japan.
J Cardiol ; 71(1): 52-58, 2018 Jan.
Article en En | MEDLINE | ID: mdl-29183566
ABSTRACT

BACKGROUND:

Although fractional flow reserve (FFR) measurements during coronary angiography are performed in routine clinical practice, few studies have evaluated FFR measurements in dialysis patients.

METHODS:

We retrospectively studied 42 hemodialysis patients with suspected or known coronary artery disease (CAD) who underwent stress myocardial perfusion imaging and coronary angiography with FFR measurements for 61 coronary lesions. The cut-off value for FFR to detect myocardial ischemia was determined by receiver operating characteristic (ROC) curve analysis.

RESULTS:

There were 61 coronary vessels measured by FFR. The FFR range was 0.34-0.93 with a mean of 0.74±0.13. The ROC curve analysis revealed that the best cut-off value of FFR for detecting myocardial ischemia was 0.76 (p<0.0001), with 70% sensitivity, 86% specificity, and 76% accuracy for myocardial ischemia. Compared with patients who had positive myocardial ischemia and an FFR≤0.76, those who had negative myocardial ischemia despite an FFR≤0.76 had less left ventricular (LV) mass index, whereas patients who had positive myocardial ischemia despite an FFR>0.76 had greater LV mass indexor serum calcium-phosphorus product.

CONCLUSIONS:

The cut-off value of FFR for myocardial ischemia in chronic hemodialysis patients is similar to that in other CAD patients. However, caution is necessary when FFR measurements are applied to dialysis patients with significantly increased LV mass index or serum calcium-phosphorus product.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Isquemia Miocárdica / Reserva del Flujo Fraccional Miocárdico Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiol Asunto de la revista: CARDIOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Isquemia Miocárdica / Reserva del Flujo Fraccional Miocárdico Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiol Asunto de la revista: CARDIOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Japón
...