Your browser doesn't support javascript.
loading
Throwing the dart blind-folded: comparison of computed tomography versus magnetic resonance imaging-guided brachytherapy for cervical cancer with regard to dose received by the 'actual' targets and organs at risk.
Yip, Winnie Wing Ling; Wong, Joyce Siu Yu; Lee, Venus Wan Yan; Wong, Frank Chi Sing; Tung, Stewart Yuk.
Afiliación
  • Yip WWL; Department of Clinical Oncology, Tuen Mun Hospital, Tuen Mun, Hong Kong.
  • Wong JSY; Department of Clinical Oncology, Tuen Mun Hospital, Tuen Mun, Hong Kong.
  • Lee VWY; Department of Clinical Oncology, Tuen Mun Hospital, Tuen Mun, Hong Kong.
  • Wong FCS; Department of Clinical Oncology, Tuen Mun Hospital, Tuen Mun, Hong Kong.
  • Tung SY; Department of Clinical Oncology, Tuen Mun Hospital, Tuen Mun, Hong Kong.
J Contemp Brachytherapy ; 9(5): 446-452, 2017 Oct.
Article en En | MEDLINE | ID: mdl-29204165
ABSTRACT

PURPOSE:

Computed tomography (CT) is inferior to magnetic resonance imaging (MRI) in cervical tumor delineation, but similar in identification of organs at risk (OAR). The trend to over-estimate high-risk and low-risk clinical target volume (HRCTV, IRCTV) on CT can lead to under-estimation of dose received by 90% (D90) of the 'actual' CTV. This study aims to evaluate whether CT-guided planning delivers adequate dose to the 'actual' targets while spares the OAR similarly. MATERIAL AND

METHODS:

MRI-guided high-dose-rate image-guided brachytherapy (IGBT) was performed in 11 patients. The pre-brachytherapy CTs were retrospectively contoured to generate CT-guided plans. MRI-based contours (HRCTVmri, IRCTVmri, bladdermri, rectummri, and sigmoidmri) were fused to CT plans for dosimetric comparison with MRI-guided plans. Paired 2-tailed t-test and Wilcoxon signed-rank test were used to analyze data.

RESULTS:

63.6% of CT plans achieved the HRCTVmriD90 constraint (≥ 7.2 Gy in one fraction), compared with 90.9% for MRI plans. > 90% of both modalities achieved the OAR's constraints (EMBRACE). The percentage of CT and MRI plans that achieved the aims (EMBRACE II) for bladder, rectum, and sigmoid were 36.4% vs. 81.8%, 63.6% vs. 63.6%, and 72.7% vs. 72.7%, respectively. There were no statistically significant differences in HRCTVmriD90, IRCTVmriD90, or dose received by the most exposed 2 cm3 (D2cc) of OARmri between the modalities. Excluding the CT plans not achieving HRCTVmriD90 constraint, there were significant increase in bladdermriD2cc, rectummriD2cc, and sigmoidmriD2cc, compared with MRI plans (0.9 Gy/Fr, 95% CI 0.2-1.5, p = 0.018; 0.9 Gy/Fr, 95% CI 0.3-1.4, p = 0.009; 0.5 Gy/Fr, 95% CI 0.2-0.9, p = 0.027, respectively).

CONCLUSIONS:

MRI-based IGBT remains the gold standard. CT planning may compromise HRCTVmriD90 or increase OARmriD2cc, which could decrease local control or increase treatment toxicity.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Etiology_studies / Risk_factors_studies Idioma: En Revista: J Contemp Brachytherapy Año: 2017 Tipo del documento: Article País de afiliación: Hong Kong

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Etiology_studies / Risk_factors_studies Idioma: En Revista: J Contemp Brachytherapy Año: 2017 Tipo del documento: Article País de afiliación: Hong Kong
...