Your browser doesn't support javascript.
loading
Measurement variability of liver metastases from neuroendocrine tumors on different magnetic resonance imaging sequences.
Lestra, T; Kanagaratnam, L; Mulé, S; Janvier, A; Brixi, H; Cadiot, G; Dohan, A; Hoeffel, C.
Afiliación
  • Lestra T; Department of radiology, Reims university hospital, 51092 Reims, France. Electronic address: tlestra@chu-reims.fr.
  • Kanagaratnam L; Department of research and innovation, Reims university hospital, 51100 Reims, France.
  • Mulé S; Department of radiology, Reims university hospital, 51092 Reims, France.
  • Janvier A; Department of radiology, Reims university hospital, 51092 Reims, France.
  • Brixi H; Department of gasto-enterology, Reims university hospital, 51100 Reims, France.
  • Cadiot G; Department of gasto-enterology, Reims university hospital, 51100 Reims, France.
  • Dohan A; Department of radiology A, Hopital Cochin, and University Paris 5-Descartes, 75014 Paris, France.
  • Hoeffel C; Department of radiology, Reims university hospital, 51092 Reims, France; Reims university hospital, CRESTIC, Champagne-Ardenne university, 51867 Reims, France.
Diagn Interv Imaging ; 99(2): 73-81, 2018 Feb.
Article en En | MEDLINE | ID: mdl-29339222
PURPOSE: To assess dimension measurement variability of liver metastases from neuroendocrine tumors (LMNET) on different magnetic resonance imaging (MRI) sequences. MATERIAL AND METHODS: In this institutional review board-approved retrospective study from January 2011 to December 2012, all liver MRI examinations performed at our department in patients with at least one measurable LMNET according to response evaluation criteria in solid tumors (RECIST1.1) were included. Up to two lesions were selected on T2-weighted MR images. Three reviewers independently measured long axes of 135 hepatic metastases in 30 patients (16 men, 14 women, mean age 61±11.4 (SD) years; range 28-78 years), during two separate reading sessions, on T2-weighted, diffusion-weighted MRI (DWI) (b; 50, 400, 800 s/mm2) and arterial, portal and late phases after intravenous administration of a gadolinium chelate. Intraclass-correlation coefficients and Bland-Altman plots were used to assess intra-and interobserver variability. RESULTS: Intra- and interobserver agreements ranged between 0.87-0.98, and 0.88-0.97, respectively. Intersequence agreements ranged between 0.92 [95%CI: 0.82-0.98] and 0.98 [95%CI: 0.93-0.99]. 95% limits of agreement for measurements were -10.2%,+8.9% for DWI (b=50s/mm2) versus -21.9%,+24.2% and -15.8,+17.2% for arterial and portal phases, respectively. CONCLUSION: An increase<9% in measurement and a decrease of -10% on DWI should not be considered as true changes, with 95% confidence, versus 24% and -22% on arterial and 17%, -16% on portal phases, respectively. DWI might thus be the most reliable MR sequence for monitoring size variations of LMNETs.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Variaciones Dependientes del Observador / Tumores Neuroendocrinos / Neoplasias Hepáticas Tipo de estudio: Observational_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Diagn Interv Imaging Año: 2018 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Variaciones Dependientes del Observador / Tumores Neuroendocrinos / Neoplasias Hepáticas Tipo de estudio: Observational_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Diagn Interv Imaging Año: 2018 Tipo del documento: Article
...