Process analytical technology in continuous manufacturing of a commercial pharmaceutical product.
Vargas, Jenny M; Nielsen, Sarah; Cárdenas, Vanessa; Gonzalez, Anthony; Aymat, Efrain Y; Almodovar, Elvin; Classe, Gustavo; Colón, Yleana; Sanchez, Eric; Romañach, Rodolfo J.
Afiliación
  • Vargas JM; Department of Chemistry, University of Puerto Rico, Mayaguez, United States; Janssen Ortho LLC-Gurabo, PR, United States.
  • Nielsen S; Janssen Supply Chain, Johnson & Johnson, New Brunswick, NJ, United States.
  • Cárdenas V; Department of Chemistry, University of Puerto Rico, Mayaguez, United States.
  • Gonzalez A; Janssen Ortho LLC-Gurabo, PR, United States.
  • Aymat EY; Janssen Ortho LLC-Gurabo, PR, United States.
  • Almodovar E; Janssen Ortho LLC-Gurabo, PR, United States.
  • Classe G; Janssen Ortho LLC-Gurabo, PR, United States.
  • Colón Y; Janssen Ortho LLC-Gurabo, PR, United States.
  • Sanchez E; Janssen Ortho LLC-Gurabo, PR, United States.
  • Romañach RJ; Department of Chemistry, University of Puerto Rico, Mayaguez, United States. Electronic address: rodolfoj.romanach@upr.edu.
Int J Pharm ; 538(1-2): 167-178, 2018 Mar 01.
Article en En | MEDLINE | ID: mdl-29355655
ABSTRACT
The implementation of process analytical technology and continuous manufacturing at an FDA approved commercial manufacturing site is described. In this direct compaction process the blends produced were monitored with a Near Infrared (NIR) spectroscopic calibration model developed with partial least squares (PLS) regression. The authors understand that this is the first study where the continuous manufacturing (CM) equipment was used as a gravimetric reference method for the calibration model. A principal component analysis (PCA) model was also developed to identify the powder blend, and determine whether it was similar to the calibration blends. An air diagnostic test was developed to assure that powder was present within the interface when the NIR spectra were obtained. The air diagnostic test as well the PCA and PLS calibration model were integrated into an industrial software platform that collects the real time NIR spectra and applies the calibration models. The PCA test successfully detected an equipment malfunction. Variographic analysis was also performed to estimate the sampling analytical errors that affect the results from the NIR spectroscopic method during commercial production. The system was used to monitor and control a 28 h continuous manufacturing run, where the average drug concentration determined by the NIR method was 101.17% of label claim with a standard deviation of 2.17%, based on 12,633 spectra collected. The average drug concentration for the tablets produced from these blends was 100.86% of label claim with a standard deviation of 0.4%, for 500 tablets analyzed by Fourier Transform Near Infrared (FT-NIR) transmission spectroscopy. The excellent agreement between the mean drug concentration values in the blends and tablets produced provides further evidence of the suitability of the validation strategy that was followed.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Preparaciones Farmacéuticas / Química Farmacéutica / Tecnología Farmacéutica / Espectroscopía Infrarroja Corta Idioma: En Revista: Int J Pharm Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Preparaciones Farmacéuticas / Química Farmacéutica / Tecnología Farmacéutica / Espectroscopía Infrarroja Corta Idioma: En Revista: Int J Pharm Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos
...