Your browser doesn't support javascript.
loading
Influence of blood contamination during multimode adhesive application on the microtensile bond strength to dentin.
Kucukyilmaz, E; Celik, E U; Akcay, M; Yasa, B.
Afiliación
  • Kucukyilmaz E; Department of Pediatric Dentistry, Faculty of Dentistry, Izmir Katip Celebi University, Cigli, Izmir, Turkey.
  • Celik EU; Department of Restorative Dentistry, Faculty of Dentistry, Izmir Katip Celebi University, Cigli, Izmir, Turkey.
  • Akcay M; Department of Pediatric Dentistry, Faculty of Dentistry, Izmir Katip Celebi University, Cigli, Izmir, Turkey.
  • Yasa B; Department of Restorative Dentistry, Faculty of Dentistry, Izmir Katip Celebi University, Cigli, Izmir, Turkey.
Niger J Clin Pract ; 20(12): 1644-1650, 2017 Dec.
Article en En | MEDLINE | ID: mdl-29379001
OBJECTIVES: The present study evaluated the effects of blood contamination performed at different steps of bonding on the microtensile bond strength (µTBS) of multimode adhesives to dentin when using the self-etch approach. MATERIALS AND METHODS: Seventy-five molars were randomly assigned to three adhesive groups comprising 25 specimens each: two multimode adhesives [Single Bond Universal (SBU) and All-Bond Universal (ABU)] and a conventional one-step self-etch adhesive [Clearfil S3 Bond Plus (CSBP)]. Each group was subdivided as follows: (1) uncontaminated (control): bonding application/light curing as a positive control; (2) contamination-1 (cont-1): bonding application/light curing/blood contamination/dry as a negative control; (3) contamination-2 (cont-2): bonding application/light curing/blood contamination/rinse/dry; (4) contamination-3 (cont-3): bonding application/blood contamination/dry/bonding re-application/light curing; and (5) contamination-4 (cont-4): bonding application/blood contamination/rinse/dry/bonding re-application/light curing. Dentin specimens were prepared for µTBS testing after the composite resin application. Data were analyzed with two-way ANOVA and post-hoc tests (α = 0.05). RESULTS: µTBS values were similar in cont-3 groups, and ABU/cont-4 and corresponding control groups, but were significantly lower in the other groups than in their control groups (P < 0.05). Cont-1 groups showed the lowest µTBS values (P < 0.05). CONCLUSIONS: Neither decontamination method prevented the decrease in µTBS when contamination occurred after light curing. Drying the blood contaminants and reapplying the adhesive may regain the dentin adhesion when contamination occurs before light curing. Alternatively, rinsing and drying contaminants followed by adhesive re-application may be effective depending on adhesive type.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Resistencia a la Tracción / Sangre / Adhesivos / Recubrimiento Dental Adhesivo / Recubrimientos Dentinarios / Diente Molar Tipo de estudio: Clinical_trials Límite: Humans Idioma: En Revista: Niger J Clin Pract Asunto de la revista: MEDICINA Año: 2017 Tipo del documento: Article País de afiliación: Turquía

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Resistencia a la Tracción / Sangre / Adhesivos / Recubrimiento Dental Adhesivo / Recubrimientos Dentinarios / Diente Molar Tipo de estudio: Clinical_trials Límite: Humans Idioma: En Revista: Niger J Clin Pract Asunto de la revista: MEDICINA Año: 2017 Tipo del documento: Article País de afiliación: Turquía
...