Development and Validation of a UPLC-MS/MS and UPLC-HR-MS Method for the Determination of Fumonisin B1 and Its Hydrolysed Metabolites and Fumonisin B2 in Broiler Chicken Plasma.
De Baere, Siegrid; Croubels, Siska; Novak, Barbara; Bichl, Gerlinde; Antonissen, Gunther.
Afiliación
  • De Baere S; Department of Pharmacology, Toxicology and Biochemistry, Salisburylaan 133, 9820 Merelbeke, Belgium. Siegrid.DeBaere@ugent.be.
  • Croubels S; Department of Pharmacology, Toxicology and Biochemistry, Salisburylaan 133, 9820 Merelbeke, Belgium. Siska.Croubels@ugent.be.
  • Novak B; BIOMIN Research Center, Technopark 1, 3430 Tulln, Austria. barbara.novak@biomin.net.
  • Bichl G; BIOMIN Research Center, Technopark 1, 3430 Tulln, Austria. gerlinde.bichl@biomin.net.
  • Antonissen G; Department of Pharmacology, Toxicology and Biochemistry, Salisburylaan 133, 9820 Merelbeke, Belgium. Gunther.Antonissen@ugent.be.
Toxins (Basel) ; 10(2)2018 01 31.
Article en En | MEDLINE | ID: mdl-29385109
ABSTRACT
A sensitive and specific method for the quantitative determination of Fumonisin B1 (FB1), its partially hydrolysed metabolites pHFB1a+b and hydrolysed metabolite HFB1, and Fumonisin B2 (FB2) in broiler chicken plasma using ultra-performance liquid chromatography combined with tandem mass spectrometry (UPLC-MS/MS) was developed. The sample preparation was rapid, straightforward and consisted of a deproteinization and phospholipid removal step using an Oasis® OstroTM 96-well plate. Chromatography was performed on an Acquity HSS-T3 column, using 0.3% formic acid and 10 mM ammonium formate in water, and acetonitrile as mobile phases. The MS/MS instrument was operated in the positive electrospray ionization mode and the two multiple reaction monitoring transitions were monitored for each component for quantification and identification, respectively. The method was validated in-house matrix-matched calibration graphs were prepared and good linearity (r ≥ 0.99) was achieved over the concentration ranges tested (1-500 ng/mL for FB1 and FB2; 0.86-860 ng/mL for pHFB1a; 0.72-1430 ng/mL for pHFB1b and 2.5-2500 ng/mL for HFB1). Limits of quantification (LOQ) and detection (LOD) in plasma ranged between 0.72 to 2.5 ng/mL and 0.03 to 0.17 ng/mL, respectively. The results for the within-day and between-day precision and accuracy fell within the specified ranges. Moreover, the method was transferred to an UPLC high-resolution mass spectrometry (HR-MS) instrument in order to determine potential metabolites of HFB1, such as N-acyl-HFB1s and phase II metabolites. The method has been successfully applied to investigate the toxicokinetics and biotransformation of HFB1 in broiler chickens.