Your browser doesn't support javascript.
loading
Macrocyclic glycopeptide chiral selectors bonded to core-shell particles enables enantiopurity analysis of the entire verubecestat synthetic route.
Barhate, Chandan L; Lopez, Diego A; Makarov, Alexey A; Bu, Xiaodong; Morris, William J; Lekhal, Azzeddine; Hartman, Robert; Armstrong, Daniel W; Regalado, Erik L.
Afiliación
  • Barhate CL; Department of Chemistry, University of Texas at Arlington, Arlington, TX 76019, USA.
  • Lopez DA; Department of Chemistry, University of Texas at Arlington, Arlington, TX 76019, USA.
  • Makarov AA; Process Research and Development, MRL, Merck & Co., Inc., Rahway, NJ 07065, USA.
  • Bu X; Process Research and Development, MRL, Merck & Co., Inc., Rahway, NJ 07065, USA.
  • Morris WJ; Process Research and Development, MRL, Merck & Co., Inc., Rahway, NJ 07065, USA.
  • Lekhal A; Process Research and Development, MRL, Merck & Co., Inc., Rahway, NJ 07065, USA.
  • Hartman R; Process Research and Development, MRL, Merck & Co., Inc., Rahway, NJ 07065, USA.
  • Armstrong DW; Department of Chemistry, University of Texas at Arlington, Arlington, TX 76019, USA.
  • Regalado EL; Process Research and Development, MRL, Merck & Co., Inc., Rahway, NJ 07065, USA. Electronic address: erik.regalado@merck.com.
J Chromatogr A ; 1539: 87-92, 2018 Mar 02.
Article en En | MEDLINE | ID: mdl-29397980
Verubecestat is an inhibitor of ß-site amyloid precursor protein cleaving enzyme 1 (BACE1) being evaluated in clinical trials for the treatment of Alzheimer's disease. Synthetic route development involves diastereoselective transformations with a need for enantiomeric excess (ee) determination of each intermediate and final active pharmaceutical ingredient (API). The analytical technical package of validated methods relies on enantioselective SFC and RPLC separations using multiple 3 and 5 µm coated polysaccharide-based chiral stationary phases (CSPs) and mobile phases combinations. Evaluation of recently developed chiral columns revealed a single chiral selector (Teicoplanin) bonded to 2.7 µm core-shell particles using H3PO4 in H2O/ACN and triethylammonium acetate: methanol based eluents at different isocratic compositions allowed good enatioseparation of all verubecestat intermediates. EE determination of verubecestat is easily performed on NicoShell, another macrocyclic glycopeptide chiral selector bonded to 2.7 µm superficially porous particles. This approach enables fast and reliable enantiopurity analysis of the entire verubecestat synthetic route using only two chiral columns and mobile phases on a conventional HPLC system, simplifying technical package preparation, method validation and transfer to manufacturing facilities.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tiadiazinas / Glicopéptidos / Técnicas de Química Analítica / Óxidos S-Cíclicos Idioma: En Revista: J Chromatogr A Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tiadiazinas / Glicopéptidos / Técnicas de Química Analítica / Óxidos S-Cíclicos Idioma: En Revista: J Chromatogr A Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos
...