Your browser doesn't support javascript.
loading
Comparative Evaluation of Stress Distribution in Experimentally Designed Nickel-titanium Rotary Files with Varying Cross Sections: A Finite Element Analysis.
Basheer Ahamed, Shadir Bughari; Vanajassun, Purushothaman Pranav; Rajkumar, Kothandaraman; Mahalaxmi, Sekar.
Afiliación
  • Basheer Ahamed SB; Department of Conservative Dentistry and Endodontics, SRM Dental College, Chennai, India.
  • Vanajassun PP; Department of Conservative Dentistry and Endodontics, SRM Dental College, Chennai, India. Electronic address: docpranav@gmail.com.
  • Rajkumar K; Department of Conservative Dentistry and Endodontics, SRM Dental College, Chennai, India.
  • Mahalaxmi S; Department of Conservative Dentistry and Endodontics, SRM Dental College, Chennai, India.
J Endod ; 44(4): 654-658, 2018 Apr.
Article en En | MEDLINE | ID: mdl-29426643
ABSTRACT

INTRODUCTION:

Single cross-sectional nickel-titanium (NiTi) rotary instruments during continuous rotations are subjected to constant and variable stresses depending on the canal anatomy. This study was intended to create 2 new experimental, theoretic single-file designs with combinations of triple U (TU), triangle (TR), and convex triangle (CT) cross sections and to compare their bending stresses in simulated root canals with a single cross-sectional instrument using finite element analysis.

METHODS:

A 3-dimensional model of the simulated root canal with 45° curvature and NiTi files with 5 cross-sectional designs were created using Pro/ENGINEER Wildfire 4.0 software (PTC Inc, Needham, MA) and ANSYS software (version 17; ANSYS, Inc, Canonsburg, PA) for finite element analysis. The NiTi files of 3 groups had single cross-sectional shapes of CT, TR, and TU designs, and 2 experimental groups had a CT, TR, and TU (CTU) design and a TU, TR, and CT (UTC) design. The file was rotated in simulated root canals to analyze the bending stress, and the von Mises stress value for every file was recorded in MPa. Statistical analysis was performed using the Kruskal-Wallis test and the Bonferroni-adjusted Mann-Whitney test for multiple pair-wise comparison with a P value <.05 (95 %).

RESULTS:

The maximum bending stress of the rotary file was observed in the apical third of the CT design, whereas comparatively less stress was recorded in the CTU design. The TU and TR designs showed a similar stress pattern at the curvature, whereas the UTC design showed greater stress in the apical and middle thirds of the file in curved canals. All the file designs showed a statistically significant difference.

CONCLUSIONS:

The CTU designed instruments showed the least bending stress on a 45° angulated simulated root canal when compared with all the other tested designs.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Instrumentos Dentales / Aleaciones Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: J Endod Año: 2018 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Instrumentos Dentales / Aleaciones Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: J Endod Año: 2018 Tipo del documento: Article País de afiliación: India
...