Your browser doesn't support javascript.
loading
Copper Nanoparticle and Nitrogen Doped Graphite Oxide Based Biosensor for the Sensitive Determination of Glucose.
Sivasankar, Kulandaivel; Rani, Karuppasamy Kohila; Wang, Sea-Fue; Devasenathipathy, Rajkumar; Lin, Chia-Her.
Afiliación
  • Sivasankar K; Department of Chemistry, Chung-Yuan Christian University, Chungli District, Taoyuan City 32023, Taiwan. sivasankarmpm@gmail.com.
  • Rani KK; Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, No. 1, Sec. 3, Chung-Hsiao East Rd., Taipei 106, Taiwan. kokirackz@gmail.com.
  • Wang SF; Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, No. 1, Sec. 3, Chung-Hsiao East Rd., Taipei 106, Taiwan. sfwang@ntut.edu.tw.
  • Devasenathipathy R; Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, No. 1, Sec. 3, Chung-Hsiao East Rd., Taipei 106, Taiwan. chemrackz@gmail.com.
  • Lin CH; Department of Chemistry, Chung-Yuan Christian University, Chungli District, Taoyuan City 32023, Taiwan. chiaher@cycu.edu.tw.
Nanomaterials (Basel) ; 8(6)2018 Jun 13.
Article en En | MEDLINE | ID: mdl-29899253
Copper nanoparticles with the diameter of 50 ± 20 nm decorated nitrogen doped graphite oxide (NGO) have been prepared through a simple single step carbonization method using copper metal-organic framework (MOF), [Cu2(BDC)2(DABCO)] (where BDC is 1,4-benzenedicarboxylate, and DABCO is 1,4-Diazabicyclo[2.2.2]octane) as precursor. The surface morphology, porosity, surface area and elemental composition of CuNPs/NGO were characterized by various techniques. The as-synthesized CuNPs/NGO nanomaterials were coated on commercially available disposable screen-printed carbon electrode for the sensitive determination of glucose. We find that the modified electrode can detect glucose between 1 μM and 1803 μM (linear range) with good sensitivity (2500 μA mM−1 cm−2). Our glucose sensor also possesses low limits of detection (0.44 μM) towards glucose determination. The highly selective nature of the fabricated electrode was clearly visible from the selectivity studies. The practicability of CuNPs/NGO modified electrode has been validated in the human serum samples. The storage stability along with better repeatability and reproducibility results additionally substantiate the superior electrocatalytic activity of our constructed sensor towards glucose.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Nanomaterials (Basel) Año: 2018 Tipo del documento: Article País de afiliación: Taiwán

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Nanomaterials (Basel) Año: 2018 Tipo del documento: Article País de afiliación: Taiwán
...