Your browser doesn't support javascript.
loading
An HPLC-MS/MS method for the simultaneous determination of luteolin and its major metabolites in rat plasma and its application to a pharmacokinetic study.
Shi, Fuguo; Pan, Hong; Lu, Yuanfu; Ding, Li.
Afiliación
  • Shi F; Key Laboratory of Basic Pharmacology of Ministry of Education and Joint International Research Laboratory of Ethnomedicine of Ministry of Education, Zunyi Medical University, Zunyi, P. R. China.
  • Pan H; Department of Pharmaceutical Analysis, Key Laboratory of Drug Quality control and Pharmacovigilance of Ministry of Education, China Pharmaceutical University, Nanjing, P. R. China.
  • Lu Y; Key Laboratory of Basic Pharmacology of Ministry of Education and Joint International Research Laboratory of Ethnomedicine of Ministry of Education, Zunyi Medical University, Zunyi, P. R. China.
  • Ding L; Department of Pharmaceutical Analysis, Key Laboratory of Drug Quality control and Pharmacovigilance of Ministry of Education, China Pharmaceutical University, Nanjing, P. R. China.
J Sep Sci ; 41(20): 3830-3839, 2018 Oct.
Article en En | MEDLINE | ID: mdl-30101558
ABSTRACT
A selective and accurate HPLC-MS/MS method was established to simultaneously quantify luteolin and its active metabolites (diosmetin, chryseriol, and luteolin-7-O-glucuronide) in rat plasma. The analytes were separated on a C18 column with a mobile phase of water containing 0.5% formic acid and acetonitrile under gradient elution to shorten the total chromatographic run time and increase the resolution of diosmetin and chryseriol. A triple quadruple mass spectrometer coupled with an electrospray ionization source in the negative ion mode was used to detect the analytes. The multiple reaction monitoring transitions were of m/z 284.9→132.9 for luteolin, m/z 298.9→283.9 for diosmetin and chryseriol, m/z 461.1→284.9 for luteolin-7-O-glucuronide, and m/z 300.9→150.9 for the internal standard. The method was linear within the concentration ranges of 0.06-90 µg/mL for luteolin, 0.03-12 µg/mL for diosmetin, 0.015-4.8 µg/mL for chryseriol, and 0.06-60 µg/mL for luteolin-7-O-glucuronide. The intra- and interday precisions were all within 6.0%. Accuracy ranged from -3.2 to 6.4%. The matrix effect and instability were not observed during bioanalysis. This method was used to study the pharmacokinetic characteristics of luteolin and its metabolites in rats after treatment with luteolin.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Flavonoides / Flavonas / Luteolina Límite: Animals Idioma: En Revista: J Sep Sci Año: 2018 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Flavonoides / Flavonas / Luteolina Límite: Animals Idioma: En Revista: J Sep Sci Año: 2018 Tipo del documento: Article
...