Your browser doesn't support javascript.
loading
Performance Evaluation of the Beckman Coulter DxN VERIS Hepatitis B Virus (HBV) Assay in Comparison With the Abbott RealTime HBV Assay.
Park, Joonhong; Cho, Hanwool; Choi, Seung Jun; Lee, Gun Dong; Sin, Sang Hyun; Ryu, Ji Hyeong; Park, Hye Sun; Lee, Hyeyoung; Kim, Yonggoo; Oh, Eun Jee.
Afiliación
  • Park J; Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Cho H; Catholic Laboratory Development and Evaluation Center, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Choi SJ; Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Lee GD; Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Sin SH; Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Ryu JH; Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Park HS; Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Lee H; Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Kim Y; Department of Laboratory Medicine, Samkwang Medical Laboratories, Seoul, Korea.
  • Oh EJ; Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Ann Lab Med ; 39(1): 86-90, 2019 Jan.
Article en En | MEDLINE | ID: mdl-30215235
ABSTRACT
The detection and quantification of hepatitis B virus (HBV) DNA plays an important role in diagnosing and monitoring HBV infection as well as in assessing the therapeutic response. We compared the analytical performance of a random access, fully automated HBV assay-DxN VERIS Molecular Diagnostics System (Beckman Coulter, Brea, CA, USA)-with that of Abbott RealTime HBV assay (Abbott Laboratories, Des Plaines, IL, USA). The between-day precision of the VERIS assay ranged from 0.92% (mean 4.68 log IU/mL) to 4.15% (mean 2.09 log IU/mL) for pooled sera from HBV patients. HBV DNA levels measured by the VERIS HBV assay correlated with the calculated HBV DNA levels (r²=0.9994; P<0.0001). The lower limit of quantification was estimated as 8.76 IU/mL (Probit analysis, 95% confidence interval 7.32-12.00 IU/mL). Passing-Bablok regression analysis showed good concordance between the VERIS and RealTime assays for 187 chronic HBV samples (y=-0.2397+0.9712x; r=0.981), as well as for 20 drug-resistant HBV genotype C positive samples (y=-0.5415+0.9954x; r=0.961). The VERIS assay demonstrated performance similar to the RealTime assay and is suitable for high-throughput HBV DNA monitoring in large hospital laboratories.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: ADN Viral / Virus de la Hepatitis B / Reacción en Cadena en Tiempo Real de la Polimerasa Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Humans Idioma: En Revista: Ann Lab Med Año: 2019 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: ADN Viral / Virus de la Hepatitis B / Reacción en Cadena en Tiempo Real de la Polimerasa Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Humans Idioma: En Revista: Ann Lab Med Año: 2019 Tipo del documento: Article
...