Shear-Wave Elastography in the Characterization of Pleural Effusions.
Ozgokce, Mesut; Durmaz, Fatma; Yavuz, Alpaslan; Üney, Ibrahim; Yildiz, Hanifi; Arslan, Harun; Dundar, Ilyas; Havan, Nuri; Ogul, Hayri.
Afiliación
  • Ozgokce M; Departments of Radiology and.
  • Durmaz F; Departments of Radiology and.
  • Yavuz A; Departments of Radiology and.
  • Üney I; Chest Disease, Medical Faculty, Yuzuncu Yil University, Van.
  • Yildiz H; Chest Disease, Medical Faculty, Yuzuncu Yil University, Van.
  • Arslan H; Departments of Radiology and.
  • Dundar I; Departments of Radiology and.
  • Havan N; Department of Radiology, Kartal Kosuyolu Researching And Training Hospital, Istanbul.
  • Ogul H; Department of Radiology, Medical Faculty, Ataturk University, Erzurum, Turkey.
Ultrasound Q ; 35(2): 164-168, 2019 Jun.
Article en En | MEDLINE | ID: mdl-30724867
ABSTRACT
The aim of the study was to investigate the efficacy of shear-wave elastography (SWE) in the differentiation of transudative and exudative pleural effusions. This monocentric study comprised 60 cases (17 transudative, 43 exudative).Transthoracic SWE was performed in 60 cases for whom to use thoracentesis for the pleural fluid analysis was planned. The mean SWE values of each patient were recorded, and the correlation between the biochemical analysis results of pleural fluid after thoracentesis and SWE findings was evaluated. The effusion SWE values and biochemical analysis results were compared. Of the 60 patients who participated in this study, 32 (53.4) were male and 28 (46.6%) were female. The mean ± SD age was 59 ± 17.09 years (range = 21-89 years). Simultaneous serum biochemical analysis was performed for the patients with PE. The mean ± SD shear-wave velocity value of the transudative fluid was calculated 2.29 ± 0.41 (1.6-2.94), whereas the mean ± SD shear-wave velocity value of the exudative pleural fluid was calculated as 3.29 ± 0.63 (2.01-4.88) (P < 0.001). The receiver operating characteristic analysis showed that sensitivity and specificity were found as 91% and 76.5%, respectively, when the cutoff value was selected as 2.52 m/s in the differentiation of the transudative and exudative effusions.Shear-wave elastography may help in the differentiation of transudative and exudative of the pleural effusions.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Derrame Pleural / Diagnóstico por Imagen de Elasticidad Tipo de estudio: Diagnostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Ultrasound Q Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2019 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Derrame Pleural / Diagnóstico por Imagen de Elasticidad Tipo de estudio: Diagnostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Ultrasound Q Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2019 Tipo del documento: Article
...