Your browser doesn't support javascript.
loading
Supercritical angle fluorescence for enhanced axial sectioning in STED microscopy.
Sivankutty, Siddharth; Coto Hernández, Iván; Bourg, Nicolas; Dupuis, Guillaume; Lévêque-Fort, Sandrine.
Afiliación
  • Sivankutty S; Institut des Sciences Moléculaires d'Orsay, CNRS, Univ. Paris-Sud, Université Paris-Saclay, F-91405 Orsay, France.
  • Coto Hernández I; Institut des Sciences Moléculaires d'Orsay, CNRS, Univ. Paris-Sud, Université Paris-Saclay, F-91405 Orsay, France.
  • Bourg N; Institut des Sciences Moléculaires d'Orsay, CNRS, Univ. Paris-Sud, Université Paris-Saclay, F-91405 Orsay, France.
  • Dupuis G; Centre Laser de l'Université Paris Sud (CLUPS/LUMAT), Univ. Paris-Sud, CNRS, Université Paris-Saclay, F-91405 Orsay, France. Electronic address: guillaume.dupuis@u-psud.fr.
  • Lévêque-Fort S; Institut des Sciences Moléculaires d'Orsay, CNRS, Univ. Paris-Sud, Université Paris-Saclay, F-91405 Orsay, France. Electronic address: sandrine.leveque-fort@u-psud.fr.
Methods ; 174: 20-26, 2020 03 01.
Article en En | MEDLINE | ID: mdl-30946895
ABSTRACT
We demonstrate subwavelength axial sectioning on biological samples with a stimulated emission depletion (STED) microscope combined with supercritical angle fluorescence (SAF) detection. SAF imaging is a powerful technique for imaging the membrane of the cell based on the direct exploitation of the fluorophore emission properties. Indeed, only when fluorophores are close to the interface can their evanescent near-field emission become propagative and be detected beyond the critical angle. Therefore, filtering out the SAF emission from the undercritical angle fluorescence (UAF) emission in the back focal plane of a high-NA objective lens permits nanometer axial sectioning of fluorescent emitters close to the coverslip. When combined with STED microscopy, a straightforward gain in axial resolution can be reached without any alteration of the STED beam path. Indeed, STED-SAF implementation only requires a modification in the detection path of the STED microscope and thus could be widely implemented.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Aumento de la Imagen / Diseño de Equipo / Microscopía Fluorescente Límite: Animals Idioma: En Revista: Methods Asunto de la revista: BIOQUIMICA Año: 2020 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Aumento de la Imagen / Diseño de Equipo / Microscopía Fluorescente Límite: Animals Idioma: En Revista: Methods Asunto de la revista: BIOQUIMICA Año: 2020 Tipo del documento: Article País de afiliación: Francia
...