Your browser doesn't support javascript.
loading
Acute toxicity and risk evaluation of the CSO disinfectants performic acid, peracetic acid, chlorine dioxide and their by-products hydrogen peroxide and chlorite.
Chhetri, Ravi Kumar; Baun, Anders; Andersen, Henrik Rasmus.
Afiliación
  • Chhetri RK; Department of Environmental Engineering, Technical University of Denmark, Bygningstorvet, Building 115, 2800 Kgs. Lyngby, Denmark.
  • Baun A; Department of Environmental Engineering, Technical University of Denmark, Bygningstorvet, Building 115, 2800 Kgs. Lyngby, Denmark.
  • Andersen HR; Department of Environmental Engineering, Technical University of Denmark, Bygningstorvet, Building 115, 2800 Kgs. Lyngby, Denmark. Electronic address: Henrik@ndersen.net.
Sci Total Environ ; 677: 1-8, 2019 Aug 10.
Article en En | MEDLINE | ID: mdl-31051379
ABSTRACT
The ecotoxicological evaluation of combined sewer overflow (CSO) disinfectants, with their degradation products, is important for ensuring safe use. For this form of toxicity, data for organisms representing different trophic levels are needed. We studied the toxicity of the alternative disinfectants peracetic acid (PAA), performic acid (PFA) and chlorine dioxide (ClO2) and their degradation products hydrogen peroxide (H2O2) and chlorite (ClO2-) on Vibrio fischeri and Daphnia magna. ClO2 was more toxic to D. magna (EC50 < 0.09 mg/L) and PFA was most toxic to V. fischeri (EC50 0.24 mg/L). EC50 of PFA, PAA, ClO2, H2O2 and ClO2- on D. magna were 0.85, 0.78, <0.09, 3.46 and 0.36 mg/L, respectively. Similarly, EC50 of PFA, PAA, ClO2, H2O2 and ClO2- on V. fischeri were 0.24, 0.42, 1.10, 5.67 and 30.93 mg/L, respectively. For both PFA and ClO2, the degradation in water was faster than for PAA, H2O2 and chlorite. Using these data together with literature values, we derived environmental quality standards. By combining these with typical concentrations of disinfectants used for CSOs, we estimated the dilution required for discharging CSOs after disinfection, which can be used for quick assessment of the environmental feasibility of disinfection systems at specific CSO sites. Minimal dilutions in the receiving water, in the orders of 44, 70 or 138-fold, are needed for ClO2, PFA and PAA, respectively. This highlights PFA as the most widely applicable disinfectant, taking into account both its efficiency and the lower risk of unwanted environmental effects.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 2_ODS3 Problema de salud: 2_enfermedades_transmissibles Asunto principal: Contaminantes Químicos del Agua / Daphnia / Aliivibrio fischeri / Desinfectantes Tipo de estudio: Etiology_studies / Risk_factors_studies Límite: Animals Idioma: En Revista: Sci Total Environ Año: 2019 Tipo del documento: Article País de afiliación: Dinamarca

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Contexto en salud: 2_ODS3 Problema de salud: 2_enfermedades_transmissibles Asunto principal: Contaminantes Químicos del Agua / Daphnia / Aliivibrio fischeri / Desinfectantes Tipo de estudio: Etiology_studies / Risk_factors_studies Límite: Animals Idioma: En Revista: Sci Total Environ Año: 2019 Tipo del documento: Article País de afiliación: Dinamarca
...