Contemporary suprasternal transcatheter aortic valve replacement: A multicenter experience using a simple, reliable alternative access approach.
Eudailey, Kyle W; Olds, Anna; Lewis, Clifton T; Nazif, Tamim N; Vahl, Torsten; Khalique, Omar K; Hahn, Rebecca T; Bapat, Vinayak; Borger, Michael A; Leon, Martin B; Ahmed, Mustafa I; Kodali, Susheel; George, Isaac.
Afiliación
  • Eudailey KW; Princeton Baptist Medical Center/Brookwood Baptist Health System, Birmingham, Alabama.
  • Olds A; Department of Surgery, Division of Cardiothoracic Surgery, College of Physicians and Surgeons of Columbia University, New York Presbyterian Hospital, New York, New York.
  • Lewis CT; Princeton Baptist Medical Center/Brookwood Baptist Health System, Birmingham, Alabama.
  • Nazif TN; Department of Surgery, Division of Cardiothoracic Surgery, College of Physicians and Surgeons of Columbia University, New York Presbyterian Hospital, New York, New York.
  • Vahl T; Department of Surgery, Division of Cardiothoracic Surgery, College of Physicians and Surgeons of Columbia University, New York Presbyterian Hospital, New York, New York.
  • Khalique OK; Department of Surgery, Division of Cardiothoracic Surgery, College of Physicians and Surgeons of Columbia University, New York Presbyterian Hospital, New York, New York.
  • Hahn RT; Department of Medicine, Division of Cardiology, College of Physicians and Surgeons of Columbia University, New York Presbyterian Hospital, New York, New York.
  • Bapat V; Department of Surgery, Division of Cardiothoracic Surgery, College of Physicians and Surgeons of Columbia University, New York Presbyterian Hospital, New York, New York.
  • Borger MA; Department of Surgery, Division of Cardiothoracic Surgery, College of Physicians and Surgeons of Columbia University, New York Presbyterian Hospital, New York, New York.
  • Leon MB; Department of Medicine, Division of Cardiology, College of Physicians and Surgeons of Columbia University, New York Presbyterian Hospital, New York, New York.
  • Ahmed MI; Princeton Baptist Medical Center/Brookwood Baptist Health System, Birmingham, Alabama.
  • Kodali S; Department of Medicine, Division of Cardiology, College of Physicians and Surgeons of Columbia University, New York Presbyterian Hospital, New York, New York.
  • George I; Department of Surgery, Division of Cardiothoracic Surgery, College of Physicians and Surgeons of Columbia University, New York Presbyterian Hospital, New York, New York.
Catheter Cardiovasc Interv ; 95(6): 1178-1183, 2020 05 01.
Article en En | MEDLINE | ID: mdl-31452322
OBJECTIVES: To describe outcomes after suprasternal (SS) transcatheter aortic valve replacement (TAVR) as a new alternative access approach. BACKGROUND: There still remains a cohort of the TAVR population who are not suitable for a transfemoral (TF) approach. SS-TAVR is a safe and effective alternative to TF-TAVR and has now become our preferred alternative access route. METHODS: We retrospectively reviewed all patients from New York Presbyterian Hospital, Columbia University Medical Center and Princeton Baptist Medical Center who underwent SS-TAVR from 2015 to July 2018. A total of 84 patients were included in the study. RESULTS: Technical success was achieved in all cases. Thirty-day survival was 98.8% (n = 83). There were minimal complications. Most notably, there were no transient ischemic attacks or strokes (0%, n = 0). Reexploration for bleeding was 3.6% (n = 3), and major bleeding was 1.7% (n = 1). We also achieved satisfactory results with a mean aortic valve gradient of 6.07 ± 3.79 mmHg and an aortic valve area of 2.21 ± 0.51 cm2 . No patients had anything more than mild paravalvular leak. The mean length of stay (LOS) in the intensive care unit was 1.42 ± 1.23 days, and hospital LOS was 4.20 ± 3.29 days. CONCLUSIONS: SS access for TAVR is an extremely important technique to have in any valve team's alternative access armamentarium. This technique can be safely and reliably reproduced with any standard hybrid operating room setup and no additional equipment, and it can be used with any commercially available valve system. In the current experience, minimal complications and excellent early term results were obtained.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male País/Región como asunto: America do norte Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2020 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male País/Región como asunto: America do norte Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2020 Tipo del documento: Article
...