Your browser doesn't support javascript.
loading
A Novel 3-Dimensional Approach for the Echocardiographic Evaluation of Mitral Valve Area After Repair for Degenerative Disease.
Karamnov, Sergey; Burbano-Vera, Nelson; Shook, Douglas C; Fox, John A; Shernan, Stanton K.
Afiliación
  • Karamnov S; From the Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts.
Anesth Analg ; 130(2): 300-306, 2020 02.
Article en En | MEDLINE | ID: mdl-31453871
BACKGROUND: Currently available 2-dimensional (2D) echocardiographic methods for accurately assessing the mitral valve orifice area (MVA) after mitral valve repair (MVr) are limited due to its complex 3-dimensional (3D) geometry. We compared repaired MVAs obtained with commonly used 2D and 3D echocardiographic methods to a 3D orifice area (3DOA), which is a novel echocardiographic measurement and independent of geometric assumptions. METHODS: Intraoperative 2D and 3D transesophageal echocardiography (TEE) images from 20 adult cardiac surgery patients who underwent MVr for mitral regurgitation obtained immediately after repair were retrospectively reviewed. MVAs obtained by pressure half-time (PHT), 2D planimetry (2DP), and 3D planimetry (3DP) were compared to those derived by 3DOA. RESULTS: MVAs (mean value ± standard deviation [SD]) after MVr were obtained by PHT (3 ± 0.6 cm), 2DP (3.58 ± 0.75 cm), 3D planimetry (3DP; 2.78 ± 0.74 cm), and 3DOA (2.32 ± 0.76 cm). MVAs obtained by the 3DOA method were significantly smaller compared to those obtained by PHT (mean difference, 0.68 cm; P = .0003), 2DP (mean difference, 1.26 cm; P < .0001), and 3DP (mean difference, 0.46 cm; P = .003). In addition, MVA defined as an area ≤1.5 cm was identified by 3DOA in 2 patients and by 3DP in 1 patient. CONCLUSIONS: Post-MVr MVAs obtained using the novel 3DOA method were significantly smaller than those obtained by conventional echocardiographic methods and may be consistent with a higher incidence of MVA reduction when compared to 2D techniques. Further studies are still needed to establish the clinical significance of 3D echocardiographic techniques used to measure MVA after MVr.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ecocardiografía Tridimensional / Válvula Mitral / Insuficiencia de la Válvula Mitral Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Anesth Analg Año: 2020 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ecocardiografía Tridimensional / Válvula Mitral / Insuficiencia de la Válvula Mitral Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Anesth Analg Año: 2020 Tipo del documento: Article
...